2-dimentional Laser Displacement SensorsLS Series
Line beam for fast, accurate measuring of height and width
- Linearity of ±0.1% F.S.
- Sampling period of 0.5 ms (max. speed)
- 2-dimensional measurements at a significantly low cost
Lineup
Type | Shape | Measurement distance | Width of view | Spot size | Model | |
---|---|---|---|---|---|---|
NPN type | PNP type | |||||
2D reflective type |
17 to 27 mm | 0.3 × 32 mm | LS-100CN | LS-100CP |
Specifications
Type | Parallel line emitting reflective type | |
---|---|---|
Model | NPN | LS-100CN |
PNP | LS-100CP | |
Measurement distance | 100 ±25 mm | |
Width of view (at measuring distance) | 17 mm (at 75 mm) to 27 mm (at 125 mm) | |
Light source | Red semiconductor laser, wavelength: 655 nm, max. output: 1 mW |
|
Laser class | IEC/JIS | Class 2 |
FDA | Class 2*1 | |
Spot size*2 | Approx. 0.3 × 32 mm | |
Linearity | Z axis | ±0.1% of F.S. |
Repeat accuracy*3 | Z axis | 2 μm |
Resolution*4 | X axis | 25 μm |
Sampling period | Typical value: 5 ms (when measuring the whole view in “Hi-res” mode), max. speed: 0.5 ms |
|
Display | Dot matrix display | |
Indicators | Power indicator (green), laser emission indicator (green) | |
External input | Selectable from bank, trigger, hold, reset, laser OFF, and offset | |
Control output | 3 NPN/PNP open collector outputs, max. 100 mA/30 VDC (max. residual voltage: 1.8 V) | |
Analog output | 4 to 20 mA, out of measurement range: 24 mA (max. load impedance: 300 Ω) |
|
Communication I/F | RS-485 half duplex (9.6 kbps to 4.0 Mbps) | |
Temperature drift (typical example) | 0.05% of F.S./℃ | |
Supply voltage | 12 to 24 VDC (±10%, including -5% ripple) | |
Current consumption*5 | Max. 180 mA | |
Environmental resistance | Degree of protection | IP67 |
Ambient temperature/humidity | -10 to +40℃/35 to 85% RH (no condensation or freezing) | |
Storage temperature/humidity | -20 to +60℃/35 to 85% RH (no condensation or freezing) | |
Ambient illuminance | Sunlight: 10000 lx or less, high-frequency lamp: 3000 lx or less | |
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions |
|
Shock resistance | Approx. 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions |
|
Applicable regulations | EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10) |
|
Applicable standards | EN 60947-5-7 | |
Warm-up time | Approx. 30 minutes | |
Material | Main unit: Zinc die-casting, PC/emitting and receiving parts: Glass |
|
Weight | Approx. 300 g |
*1 In accordance with the FDA provisions of Laser Notice No. 50, the laser is classified as Class 2 per the IEC 60825-1 standard.
*2 Defined with center strength 1/e2 (13.5%) at the center of measurement range. There may be leak light other than the specified spot
size. The sensor may be affected when there is a highly reflective object close to the detection area.
*3 With an average height measurement of a white workpiece with a center width of 5 mm, smoothing performed 8 times, moving
average performed 32 times (with the default settings)
*4 With a measurement distance of 75 mm
*5 Supply voltage: 24 VDC not including the control output load current and including the analog output