Digital Fiber AmplifiersD3RF/D3IF Series

DOWNLOAD

Easy-to-use fiber amplifiers

  •  Fastest high-speed response in the world
    Supports cross talk prevention functions for up to 2 units, even in the fastest mode
  • New generation specifi cations for sensing distance as well
  • 100% display for better recognition of level change
D3RF/D3IF Series

Lineup

Type Shape Control output Light source Model (Models in parentheses are connector types)
NPN type PNP type
Stand-alone type
Single output

4 element red LED

D3RF-TN
(D3RF-TCN4)
D3RF-TP
(D3RF-TCP4)
Dual output D3RF-TDN D3RF-TDP
Inter-connection master
Single output D3RF-TMN
(D3RF-TMCN4)
D3RF-TMP
(D3RF-TMCP4)
Dual output D3RF-TDMN D3RF-TDMP
Inter-connection slave Single output D3RF-TSN
(D3RF-TSCN4)
D3RF-TSP
(D3RF-TSCP4)
Dual output D3RF-TDSN D3RF-TDSP
Water detection
Single output Infrared LED D3IF-TN
(D3IF-TCN4)
D3IF-TP
(D3IF-TCP4)

•For connection with a UC1 communication unit, please select an inter-connection master and slave unit.

Specifications

Type Stand-alone type Inter-connection master Inter-connection slave Water detection
Mode NPN Single
output
Cable type D3RF-TN D3RF-TMN D3RF-TSN D3IF-TN
Connector type D3RF-TCN4 D3RF-TMCN4 D3RF-TSCN4 D3IF-TCN4
Dual output Cable type D3RF-TDN D3RF-TDMN D3RF-TDSN -
PNP Single
output
Cable type D3RF-TP D3RF-TMP D3RF-TSP D3IF-TP
Connector type D3RF-TCP4 D3RF-TMCP4 D3RF-TSCP4 D3IF-TCP4
Dual output Cable type D3RF-TDP D3RF-TDMP D3RF-TDSP -
Light source 4 element red LED (wavelengtd 632 nm) Infrared LED (wavelengtd 1.45 μm)
Response
time *1
1-HS mode 16 μs 16 μs (when linked 22 μs) 22 μs 16 μs
2-FS mode 70 μs 70 μs (when linked 85 μs) 85 μs 70 μs
3-ST mode 250 μs
4-LG mode 500 μs
5-PL mode 1 ms
6-UL mode 2 ms
7-EL mode 8 ms
Distance adjustment Various types of teaching and manual adjustment
Indicators Single output type: Output indicator (orange)
Dual output type: Output indicator (orange) ×2
Digital display 7-segment, 8-digit display (red: 4-digit, green: 4-digit)
Control output*2 NPN/PNP open collector Max. 100 mA*3/30 VDC,
residual voltage: 1.8 V or less
External input Teach input*4, Test input, synchronous input, counter reset input*5
Timer function ON delay, OFF delay, one-shot, ON + OFF delay,
ON + one-shot settable 0.1 to 9999 ms
Output mode Light ON / Dark ON selectable by setting
No. of connectable units
(including master unit)
Max. 16 units
Connection type Cable type: Cable length: 2 m Connector type: M8, 4-pin
Insulation resistance 20 MΩ or more (with 500 VDC)
Rating Supply voltage 12 to 24 VDC ±10%, including 10% ripple (p-p)
Power consumption
(normally)
Single output type: 864 mW (36 mA or less at 24 V)
Dual output type: 936 mW (39 mA or less at 24 V)
Power consumption
(Eco ALL)
Single output type: 600 mW (25 mA or less at 24 V)
Dual output type: 672 mW (28 mA or less at 24 V)
Applicable regulations EMC directive (2004/108/EC)
Applicable standards EN 60947-5-2
Company standards Noise resistance: Feilen Level 4 cleared
Environmental resistance Ambient temperature/humidity -25 to +55℃*6 / 35 to 85% RH (no freezing or condensation)
Ambient illuminance Sunlight: 10000 lx or less Incandescent light: 3000 lx or less
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of tde X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of tde X, Y, and Z directions
Degree of protection IP50
Material Housing, cover: PC
Weight Cable type: Approx. 71 g / Connector type: Approx. 25 g
Included accessories Mounting bracket

•Specifications are subject to change without prior notice for product improvement purposes.
*1 When Eco mode is set to rESP or ALL, the response time is doubled.
*2 For dual output types, the threshold value/timer and Light ON/Dark ON can be set individually for output 1 and output 2. Additionally,ASC is only available for output 1.
*3 No. of connectable units when used stand-alone or as the master unit: 2 to 3 units. Please use a load current of 50 mA or less for 4 to 8 units, and 20 mA or less for 9 to 16 units.
*4 Teaching mode from external input is a mode executed in advance by the main unit (default: 2-point teaching).
*5 The counter function is a function only for the dual output type, as counter reset input is not equipped to single output types.
*6 No. of connectable units when used stand-alone or as the master unit: 2 to 3 units. Keep at -25 to +50°C for 4 to 8 units, and -25 to +45℃ for 9 to 16 units.