Small Laser Displacement SensorsCD33 Series
Half-palm size. Ideal for built-in use with smaller machines.
- Specular reflection types have been added to the line up
- Control units for Mitsubishi Electric PLC are available
Lineup
Type | Measurement range | Repeat accuracy | Analog output/serial interface | Control output | Model (Models in parentheses are connector types) | |
---|---|---|---|---|---|---|
NPN type | PNP type | |||||
2 μm (4 μm*) |
4 to 20 mA | 2ch | CD33-30NA (CD33-30CNA) |
CD33-30PA (CD33-30CPA) |
||
0 to 10 V | CD33-30NV (CD33-30CNV) |
CD33-30PV (CD33-30CPV) |
||||
RS-422 | 1ch | CD33-30N-422 (CD33-30CN-422) |
CD33-30P-422 (CD33-30CP-422) |
|||
5 μm (8 μm*) |
4 to 20 mA | 2ch | CD33-50NA (CD33-50CNA) |
CD33-50PA (CD33-50CPA) |
||
0 to 10 V | CD33-50NV (CD33-50CNV) |
CD33-50PV (CD33-50CPV) |
||||
RS-422 | 1ch | CD33-50N-422 (CD33-50CN-422) |
CD33-50P-422 (CD33-50CP-422) |
|||
10 μm (15 μm*) |
4 to 20 mA | 2ch | CD33-85NA (CD33-85CNA) |
CD33-85PA (CD33-85CPA) |
||
0 to 10 V | CD33-85NV (CD33-85CNV) |
CD33-85PV (CD33-85CPV) |
||||
RS-422 | 1ch | CD33-85N-422 (CD33-85CN-422) |
CD33-85P-422 (CD33-85CP-422) |
|||
30 μm (45 μm*) |
4 to 20 mA | 2ch | CD33-120NA (CD33-120CNA) |
CD33-120PA (CD33-120CPA) |
||
0 to 10 V | CD33-120NV (CD33-120CNV) |
CD33-120PV (CD33-120CPV) |
||||
RS-422 | 1ch | CD33-120N-422 (CD33-120CN-422) |
CD33-120P-422 (CD33-120CP-422) |
|||
75 μm (100 μm*) |
4 to 20 mA | 2ch | CD33-250NA (CD33-250CNA) |
CD33-250PA (CD33-250CPA) |
||
0 to 10 V | CD33-250NV (CD33-250CNV) |
CD33-250PV (CD33-250CPV) |
||||
RS-422 | 1ch | CD33-250N-422 (CD33-250CN-422) |
CD33-250P-422 (CD33-250CP-422) |
|||
1 μm | RS-422 | 1ch | CD33-L30N-422 (CD33-L30CN-422) |
CD33-L30P-422 (CD33-L30CP-422) |
||
2.5 μm | CD33-L50N-422 (CD33-L50CN-422) |
CD33-L50P-422 (CD33-L50CP-422) |
||||
5 μm | CD33-L85N-422 (CD33-L85CN-422) |
CD33-L85P-422 (CD33-L85CP-422) |
*The repeat accuracy when response time is set to FAST is shown in parentheses.
For the connector type, please purchase an optional DOL-1208-G05MF connector cable.
When using a UQ1-02 control unit, select the RS-422 communication type.
Specifications
Diffuse-reflective type Measurement distance based specifications
Model | CD33-30☐☐☐ | CD33-50☐☐☐ | CD33-85☐☐☐ | CD33-120☐☐☐ | CD33-250☐☐☐ | |
---|---|---|---|---|---|---|
Center of measurement range | 30 mm | 50 mm | 85 mm | 120 mm | 250 mm | |
Measurement range | ±4 mm | ±10 mm | ±20 mm | ±60 mm | ±150 mm | |
F.S. (full scale) | 8 mm | 20 mm | 40 mm | 120 mm | 300 mm | |
Light source | Red semiconductor laser, wavelength: 655 nm, Maximum output: 1 mW | |||||
Laser class | IEC/JIS: CLASS 2 FDA: CLASS II | |||||
Spot size*1 | 0.1 × 0.1 mm | 0.5 × 1.0 mm | 0.75 × 1.25 mm | 1.0 × 1.5 mm | 1.75 × 3.5 mm | |
Linearity | ±0.1% F.S. | Linearity ±0.3% F.S. | ||||
Repeat accuracy | 2 μm (4 μm when response time is set to FAST) |
5 μm (8 μm when response time is set to FAST) |
10 μm (15 μm when response time is set to FAST) |
30 μm (45 μm when response time is set to FAST) |
75 μm (100 μm when response time is set to FAST) |
|
Sampling period | 0.5 ms/1 ms/1.5 ms/2 ms | 0.75 ms/1 ms/1.5 ms/2 ms | ||||
Response time*2 Averaging |
Fast | 5 ms or less: Averaging 1 time (1 ms) + sensitivity switching time (Max. 4 ms) |
7.5 ms or less: Averaging 1 time (1.5 ms) + sensitivity switching time (Max. 6 ms) |
|||
Standard | 12.5 ms or less: Averaging 16 times (8.5 ms) + sensitivity switching time (Max. 4 ms) |
19 ms or less: Averaging 16 times (13 ms) + sensitivity switching time (Max. 6 ms) |
||||
Highresolution | 36.5 ms or less: Averaging 64 times (32.5 ms) + sensitivity switching time (Max. 4 ms) |
55 ms or less: Averaging 64 times (49 ms) + sensitivity switching time (Max. 6 ms) |
||||
Temperature drift | ±0.08%/℃ F.S. | |||||
Indicators | Distance indicator | LED bar display on operation surface (25-step) | ||||
Output indicator | Q1 and Q2 LED lights up during output (orange) | |||||
Input indicator | MF LED lights up during input (orange) | |||||
MF (multi-function) input | Choose from laser OFF, teaching*3, sample & hold Response time: 3 ms or less | |||||
Connection type | Cable type: Cable length: 2 m (ø5) Connector type: M12, 8-pin | |||||
Protection circuit | Reverse connection protection, overcurrent protection function | |||||
Degree of protection | IP67 | |||||
Ambient temperature/humidity | -10 to +45℃ / 35 to 85% RH (no freezing or condensation) | |||||
Ambient illuminance | Sunlight: 10,000 lx Incandescent lamp: 3,000 lx | |||||
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions | |||||
Shock resistance | Approx. 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions | |||||
Warm-up time | Approx. 15 minutes | |||||
Material | Housing: PBT, Front cover: PMMA, Cable: PVC | |||||
Weight without cable | Approx. 65 g |
Diffuse-reflective type Output based specifications
Type | Analog current output type | Analog voltage output type | RS-422 type | |
---|---|---|---|---|
Model | NPN type | CD33-☐☐NA | CD33-☐☐NV | CD33-☐☐N-422 |
PNP type | CD33-☐☐PA | CD33-☐☐PV | CD33-☐☐P-422 | |
Supply voltage | 12 to 24 VDC, ±10/-5% | 18 to 24 VDC, ±10/-5% | 12 to 24 VDC, ±10/-5% | |
Current consumption | Max. 85 mA (including analog output | Max. 55 mA | ||
Control output | Output channel No. | 2ch: Q1, Q2 (default setting of self-diagnosis output for Q2) | 1ch: Q2 (default setting of self-diagnosis output) | |
Output method | NPN/PNP open collector output, Max. 100 mA / 30 VDC, residual voltage 1.8 V | |||
Analog output/serial interface | 4 to 20 mA, load impedance: 300 Ω or less | 0 to 10 V, output impedance: 100 Ω | RS-422 9.6 k to 256 kbps | |
Applicable regulations | EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10) | |||
Applicable standards | EN 60947-5-7 | EN 60947-5-2 |
<Measurement conditions> The measurement conditions are as follows unless otherwise designated: Ambient temperature of +23℃ (normal temperature), Supply voltage 24 VDC,
Response time: High-resolution, Center of measurement range, Measurement target: 50 ☓ 50 mm white ceramic.
*1 Defined with center strength 1/e2 (13.5%) at the center of measurement range. There may be leak light other than the specified spot size. The sensor may be affected when there is a highly reflective object in the range of the light axis.
*2 The response time is a time in which the sensitivity switching time has been added. The sensitivity switching time fluctuates within a max. range of 4 ms (6 ms for CD33-250N☐)
depending on measurement conditions. Also, if the sampling period is long, the response time will also increase proportionately.
Ex.: Sampling period 500 µs → 1000 µs: Response time 12.5 ms → Approx. 25 ms
*3 If external teaching is selected, setting items can be changed as shown in the table below depending on the input time thereof.
Setting items | Input time |
---|---|
1st point for span adjustment | 70 to 130 ms |
2nd point for span adjustment | 170 to 230 ms |
1-point teaching of control output Q1 Please input the same time for the 2nd point of 2-point teaching within one minute. |
270 to 330 ms |
Inverted 1-point teaching of control output Q1 | 370 to 430 ms |
1-point teaching of control output Q2 Please input the same time for the 2nd point of 2-point teaching within one minute. |
470 to 530 ms |
Inverted 1-point teaching of control output Q2 | 570 to 630 ms |
Offset (zero reset) | 670 to 5000 ms |
Clearing offset | 5000 ms or more |
Specular reflection type
Model | NPN type | CD33-L30☐N-422 | CD33-L50☐N-422 | CD33-L85☐N-422 |
---|---|---|---|---|
PNP type | CD33-L30☐P-422 | CD33-L50☐P-422 | CD33-L85☐P-422 | |
Measurement target object | Specular object, glass | |||
Center of measurement range | 26.3 mm | 47.3 mm | 82.9 mm | |
Measurement range | ±2 mm | ±5 mm | ±10 mm | |
F.S. (full scale) | 4 mm | 10 mm | 20 mm | |
Light source | Red semiconductor laser, wavelength: 655 nm, Maximum output: 390 μW | |||
Laser class | IEC/JIS: CLASS 1 FDA: CLASS II | |||
Spot size*1 | 0.1 × 0.1 mm | |||
Linearity | ±0.2% F.S. | |||
Repeat accuracy | 1 μm | 2.5 μm | 5 μm | |
Sampling period | 0.5 (default setting), 4-stage switching is possible between 1 ms, 1.5 ms, 2 ms | |||
Response time*2 Averaging |
Fast | 5 ms or less: Averaging 1 time (1 ms) + sensitivity switching time (Max. 4 ms) | ||
Standard | 12.5 ms or less: Averaging 16 times (8.5 ms) + sensitivity switching time (Max. 4 ms) | |||
High-resolution | 36.5 ms or less: Averaging 64 times (32.5 ms) + sensitivity switching time (Max. 4 ms) | |||
Control output |
Output channel No. | 1ch: Q2 (default setting of self-diagnosis output) | ||
Output method | NPN/PNP open collector output, Max. 100 mA / 30 VDC, residual voltage 1.8 V | |||
Analog output | Not equipped | |||
Serial interface | RS-422 9.6 k to 256 kbps | |||
Temperature drift | ±0.08%/°C F.S. | |||
Indicators | Distance indicator | LED bar display on operation surface (25-step) | ||
Output indicator | Q2 LED lights up during output (orange) | |||
Input indicator | MF LED lights up during input (orange) | |||
MF (multi-function) input | Choose from laser OFF, teaching*3, sample & hold Response time: 3 ms or less | |||
Supply voltage | 12 to 24 VDC, ±10/-5% | |||
Current consumption | Max. 55 mA | |||
Connection type | Cable type: Cable length: 2 m (ø5) Connector type: M12, 8-pin | |||
Protection circuit | Reverse connection protection, overcurrent protection function | |||
Degree of protection | IP67 | |||
Ambient temperature/humidity | -10 to +45°C / 35 to 85% RH (no freezing or condensation) | |||
Ambient illuminance | Sunlight: 10,000 lx Incandescent lamp: 3,000 lx | |||
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance | Approx. 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions |
|||
Applicable regulations | EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10) | |||
Applicable standards | EN 60947-5-2 | |||
Warm-up time | Approx. 15 minutes | |||
Material | Housing: PBT, Front cover: PMMA, Cable: PVC | |||
Weight without cable | Approx. 65 g |
*1 Defined with center strength 1/e2 (13.5%) at the center of measurement range. There may be leak light other than the specified spot size. The sensor may be affected when there
is a highly reflective object in the range of the light axis.
*2 The response time is a time in which the sensitivity switching time has been added. The sensitivity switching time fluctuates within a max. range of 4 ms depending on
measurement conditions. Also, if the sampling period is long, the response time will also increase proportionately.
Ex.: Sampling period 500 µs → 1000 µs: Response time 12.5 ms → Approx. 25 ms
*3 If external teaching is selected, setting items can be changed as shown in the table below depending on the input time thereof.
Setting items | Input time |
---|---|
1-point teaching of control output Q2 Please input the same time for the 2nd point of 2-point teaching within one minute. |
470 to 530 ms |
Inverted 1-point teaching of control output Q2 | 570 to 630 ms |
Offset (zero reset) | 670 to 5000 ms |
Clearing offset | 5000 ms or more |