Small Laser Displacement SensorsCD33 Series

DOWNLOAD

Half-palm size. Ideal for built-in use with smaller machines.

  • Specular reflection types have been added to the line up
  • Control units for Mitsubishi Electric PLC are available
CD33 Series

Lineup

Type Measurement range Repeat accuracy Analog output/serial interface Control output Model (Models in parentheses are connector types)
NPN type PNP type
2 μm
(4 μm*)
4 to 20 mA 2ch CD33-30NA
(CD33-30CNA)
CD33-30PA
(CD33-30CPA)
0 to 10 V CD33-30NV
(CD33-30CNV)
CD33-30PV
(CD33-30CPV)
RS-422 1ch CD33-30N-422
(CD33-30CN-422)
CD33-30P-422
(CD33-30CP-422)
5 μm
(8 μm*)
4 to 20 mA 2ch CD33-50NA
(CD33-50CNA)
CD33-50PA
(CD33-50CPA)
0 to 10 V CD33-50NV
(CD33-50CNV)
CD33-50PV
(CD33-50CPV)
RS-422 1ch CD33-50N-422
(CD33-50CN-422)
CD33-50P-422
(CD33-50CP-422)
10 μm
(15 μm*)
4 to 20 mA 2ch CD33-85NA
(CD33-85CNA)
CD33-85PA
(CD33-85CPA)
0 to 10 V CD33-85NV
(CD33-85CNV)
CD33-85PV
(CD33-85CPV)
RS-422 1ch CD33-85N-422
(CD33-85CN-422)
CD33-85P-422
(CD33-85CP-422)
30 μm
(45 μm*)
4 to 20 mA 2ch CD33-120NA
(CD33-120CNA)
CD33-120PA
(CD33-120CPA)
0 to 10 V CD33-120NV
(CD33-120CNV)
CD33-120PV
(CD33-120CPV)
RS-422 1ch CD33-120N-422
(CD33-120CN-422)
CD33-120P-422
(CD33-120CP-422)
75 μm
(100 μm*)
4 to 20 mA 2ch CD33-250NA
(CD33-250CNA)
CD33-250PA
(CD33-250CPA)
0 to 10 V CD33-250NV
(CD33-250CNV)
CD33-250PV
(CD33-250CPV)
RS-422 1ch CD33-250N-422
(CD33-250CN-422)
CD33-250P-422
(CD33-250CP-422)
1 μm RS-422 1ch CD33-L30N-422
(CD33-L30CN-422)
CD33-L30P-422
(CD33-L30CP-422)
2.5 μm CD33-L50N-422
(CD33-L50CN-422)
CD33-L50P-422
(CD33-L50CP-422)
5 μm CD33-L85N-422
(CD33-L85CN-422)
CD33-L85P-422
(CD33-L85CP-422)

*The repeat accuracy when response time is set to FAST is shown in parentheses.
• For the connector type, please purchase an optional DOL-1208-G05MF connector cable.
• When using a UQ1-02 control unit, select the RS-422 communication type.

Specifications

Diffuse-reflective type Measurement distance based specifications

Model CD33-30☐☐☐ CD33-50☐☐☐ CD33-85☐☐☐ CD33-120☐☐☐ CD33-250☐☐☐
Center of measurement range 30 mm 50 mm 85 mm 120 mm 250 mm
Measurement range ±4 mm ±10 mm ±20 mm ±60 mm ±150 mm
F.S. (full scale) 8 mm 20 mm 40 mm 120 mm 300 mm
Light source Red semiconductor laser, wavelength: 655 nm, Maximum output: 1 mW
Laser class IEC/JIS: CLASS 2 FDA: CLASS II
Spot size*1 0.1 × 0.1 mm 0.5 × 1.0 mm 0.75 × 1.25 mm 1.0 × 1.5 mm 1.75 × 3.5 mm
Linearity ±0.1% F.S. Linearity ±0.3% F.S.
Repeat accuracy 2 μm
(4 μm when response
time is set to FAST)
5 μm
(8 μm when response
time is set to FAST)
10 μm
(15 μm when response
time is set to FAST)
30 μm
(45 μm when response
time is set to FAST)
75 μm
(100 μm when response time is set to FAST)
Sampling period 0.5 ms/1 ms/1.5 ms/2 ms 0.75 ms/1 ms/1.5 ms/2 ms
Response
time*2
Averaging
Fast 5 ms or less: Averaging 1 time (1 ms) +
sensitivity switching time (Max. 4 ms)
7.5 ms or less: Averaging 1 time
(1.5 ms) + sensitivity switching
time (Max. 6 ms)
Standard 12.5 ms or less: Averaging 16 times (8.5 ms) +
sensitivity switching time (Max. 4 ms)
19 ms or less: Averaging 16 times
(13 ms) + sensitivity switching
time (Max. 6 ms)
Highresolution 36.5 ms or less: Averaging 64 times (32.5 ms) +
sensitivity switching time (Max. 4 ms)
55 ms or less: Averaging 64 times
(49 ms) + sensitivity switching
time (Max. 6 ms)
Temperature drift ±0.08%/℃ F.S.
Indicators Distance indicator LED bar display on operation surface (25-step)
Output indicator Q1 and Q2 LED lights up during output (orange)
Input indicator MF LED lights up during input (orange)
MF (multi-function) input Choose from laser OFF, teaching*3, sample & hold Response time: 3 ms or less
Connection type Cable type: Cable length: 2 m (ø5) Connector type: M12, 8-pin
Protection circuit Reverse connection protection, overcurrent protection function
Degree of protection IP67
Ambient temperature/humidity -10 to +45℃ / 35 to 85% RH (no freezing or condensation)
Ambient illuminance Sunlight: 10,000 lx Incandescent lamp: 3,000 lx
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions
Warm-up time Approx. 15 minutes
Material Housing: PBT, Front cover: PMMA, Cable: PVC
Weight without cable Approx. 65 g

Diffuse-reflective type Output based specifications

Type Analog current output type Analog voltage output type RS-422 type
Model NPN type CD33-☐☐NA CD33-☐☐NV CD33-☐☐N-422
PNP type CD33-☐☐PA CD33-☐☐PV CD33-☐☐P-422
Supply voltage 12 to 24 VDC, ±10/-5% 18 to 24 VDC, ±10/-5% 12 to 24 VDC, ±10/-5%
Current consumption Max. 85 mA (including analog output Max. 55 mA
Control output Output channel No. 2ch: Q1, Q2 (default setting of self-diagnosis output for Q2) 1ch: Q2 (default setting of self-diagnosis output)
Output method NPN/PNP open collector output, Max. 100 mA / 30 VDC, residual voltage 1.8 V
Analog output/serial interface 4 to 20 mA, load impedance: 300 Ω or less 0 to 10 V, output impedance: 100 Ω RS-422 9.6 k to 256 kbps
Applicable regulations EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10)
Applicable standards EN 60947-5-7 EN 60947-5-2

<Measurement conditions> The measurement conditions are as follows unless otherwise designated: Ambient temperature of +23℃ (normal temperature), Supply voltage 24 VDC, Response time: High-resolution, Center of measurement range, Measurement target: 50 ☓ 50 mm white ceramic.
*1 Defined with center strength 1/e2 (13.5%) at the center of measurement range. There may be leak light other than the specified spot size. The sensor may be affected when there is a highly reflective object in the range of the light axis.
*2 The response time is a time in which the sensitivity switching time has been added. The sensitivity switching time fluctuates within a max. range of 4 ms (6 ms for CD33-250N☐) depending on measurement conditions. Also, if the sampling period is long, the response time will also increase proportionately.
Ex.: Sampling period 500 µs → 1000 µs: Response time 12.5 ms → Approx. 25 ms
*3 If external teaching is selected, setting items can be changed as shown in the table below depending on the input time thereof.

Setting items Input time
1st point for span adjustment 70 to 130 ms
2nd point for span adjustment 170 to 230 ms
1-point teaching of control output Q1
Please input the same time for the 2nd point of 2-point teaching within one minute.
270 to 330 ms
Inverted 1-point teaching of control output Q1 370 to 430 ms
1-point teaching of control output Q2
Please input the same time for the 2nd point of 2-point teaching within one minute.
470 to 530 ms
Inverted 1-point teaching of control output Q2 570 to 630 ms
Offset (zero reset) 670 to 5000 ms
Clearing offset 5000 ms or more

Specular reflection type

Model NPN type CD33-L30☐N-422 CD33-L50☐N-422 CD33-L85☐N-422
PNP type CD33-L30☐P-422 CD33-L50☐P-422 CD33-L85☐P-422
Measurement target object Specular object, glass
Center of measurement range 26.3 mm 47.3 mm 82.9 mm
Measurement range ±2 mm ±5 mm ±10 mm
F.S. (full scale) 4 mm 10 mm 20 mm
Light source Red semiconductor laser, wavelength: 655 nm, Maximum output: 390 μW
Laser class IEC/JIS: CLASS 1 FDA: CLASS II
Spot size*1 0.1 × 0.1 mm
Linearity ±0.2% F.S.
Repeat accuracy 1 μm 2.5 μm 5 μm
Sampling period 0.5 (default setting), 4-stage switching is possible between 1 ms, 1.5 ms, 2 ms
Response
time*2
Averaging
Fast 5 ms or less: Averaging 1 time (1 ms) + sensitivity switching time (Max. 4 ms)
Standard 12.5 ms or less: Averaging 16 times (8.5 ms) + sensitivity switching time (Max. 4 ms)
High-resolution 36.5 ms or less: Averaging 64 times (32.5 ms) + sensitivity switching time (Max. 4 ms)
Control
output
Output channel No. 1ch: Q2 (default setting of self-diagnosis output)
Output method NPN/PNP open collector output, Max. 100 mA / 30 VDC, residual voltage 1.8 V
Analog output Not equipped
Serial interface RS-422 9.6 k to 256 kbps
Temperature drift ±0.08%/°C F.S.
Indicators Distance indicator LED bar display on operation surface (25-step)
Output indicator Q2 LED lights up during output (orange)
Input indicator MF LED lights up during input (orange)
MF (multi-function) input Choose from laser OFF, teaching*3, sample & hold Response time: 3 ms or less
Supply voltage 12 to 24 VDC, ±10/-5%
Current consumption Max. 55 mA
Connection type Cable type: Cable length: 2 m (ø5) Connector type: M12, 8-pin
Protection circuit Reverse connection protection, overcurrent protection function
Degree of protection IP67
Ambient temperature/humidity -10 to +45°C / 35 to 85% RH (no freezing or condensation)
Ambient illuminance Sunlight: 10,000 lx Incandescent lamp: 3,000 lx
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of the X, Y, and Z directions
Applicable regulations EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10)
Applicable standards EN 60947-5-2
Warm-up time Approx. 15 minutes
Material Housing: PBT, Front cover: PMMA, Cable: PVC
Weight without cable Approx. 65 g

The measurement conditions are as follows unless otherwise designated: Ambient temperature of +23℃ (normal temperature), Supply voltage 24 VDC, Response time: Highresolution, Center of measurement range, Measurement target: aluminum deposition mirror.
*1 Defined with center strength 1/e2 (13.5%) at the center of measurement range. There may be leak light other than the specified spot size. The sensor may be affected when there is a highly reflective object in the range of the light axis.
*2 The response time is a time in which the sensitivity switching time has been added. The sensitivity switching time fluctuates within a max. range of 4 ms depending on measurement conditions. Also, if the sampling period is long, the response time will also increase proportionately.
Ex.: Sampling period 500 µs → 1000 µs: Response time 12.5 ms → Approx. 25 ms
*3 If external teaching is selected, setting items can be changed as shown in the table below depending on the input time thereof.

Setting items Input time
1-point teaching of control output Q2
Please input the same time for the 2nd point of 2-point
teaching within one minute.
470 to 530 ms
Inverted 1-point teaching of control output Q2 570 to 630 ms
Offset (zero reset) 670 to 5000 ms
Clearing offset 5000 ms or more