Specifications
Model | TI-S30 | |
---|---|---|
Measurement range*1 | −40 to +500°C | |
Display range*1 | -50 to +510°C | |
Field of view | φ30 mm at 500 mm | |
Optics | Silicon lens | |
Sensing element/ spectral response |
Thermopile 8 to 14 μm | |
Response time (operating mode) |
High speed, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s * Output response 90%*2 |
|
Accuracy*3 | −40 to 0°C: ±1.5°C +1 to +200°C: ±1°C +201 to +500°C: ±0.5% of reading value |
|
Repeatability | ±0.5°C (when operating mode is 100 ms) | |
Temperature drift | Within ±0.25°C/°C | |
Emissivity adjustment | 0.100 to 1.200 | |
Supply voltage | 5 VDC (Supplied from controller) | |
Current consumption | 30 mA or less/5 VDC | |
Connection type | Pigtail cable 3 m | |
Minimum bending radius | R 31 mm | |
Total cable length | Max. 13 m (pigtail cable 3 m + extension cable 10 m) | |
Laser pointer | Medium | Red semiconductor laser |
Wavelength | 663 nm | |
Maximum output | 1 mW | |
Laser class (JIS/IEC/FDA)*4 | CLASS 2 | |
Environmental resistance |
Degree of protection | IP67 (IEC 60529) |
Ambient temperature | 0 to +80°C (up to +70°C during laser emission) | |
Ambient humidity | 35 to 85% RH (no condensation) | |
Storage temperature | −20 to +80°C | |
Vibration resistance | 10 to 55 Hz Double amplitude 1.5 mm 2 hours in each of the X,Y and Z directions | |
Shock resistance | 500 m/s2 (Approx. 50 G ) 3 times in each of the X,Y and Z directions | |
Applicable regulations |
EMC | EMC Directive (2014/30/EU) UK EMC (The Electromagnetic Compatibility Regulations 2016) FCC Part 15 subpart B |
Environment | RoHS Directive (2011/65/EU), China RoHS (MIIT Order No. 32) UK RoHS (The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012) |
|
Safety | FDA Regulation (21 CFR 1040.10 and 1040.11*5) | |
Applicable standards | EN/IEC 61326-1 | |
Material | Case: Aluminum, Front plate: Stainless steel | |
Weight | Approx. 180 g (including connector cable) |
*1: If the measured temperature is below -50°C (lower limit display temperature), the displayed temperature is -50°C.
If the measured temperature is above 510°C (upper limit display temperature), the displayed temperature is 510°C.
*2: The response time is the time it takes for the output change to reach 90%.
*3: Measurement conditions: Emissivity; 1.000, Ambient temperature; 23 ±5°C, Size of the measurement target; sufficiently larger than the field of view.
*4: In accordance with the FDA provisions of Laser Notice No. 56, the laser is classified per the IEC 60825-1:2014 standard.
*5: Excluding differences per Laser Notice No. 56.
* To convert temperature values such as measurement temperature range and accuracy to Fahrenheit temperature, use (Fahrenheit temperature = Celsius temperature x 1.8 + 32).
* To convert relative values such as repeatability and temperature drift to Fahrenheit temperatures, use 1°C = 1.8°F.

● Specifications are subject to change without prior notice.
Model | TI-SC (E) | ||
---|---|---|---|
Rating | Supply voltage | 24 VDC (when using a general-purpose I/O cable) 18 to 30 VDC (when using an IO-Link cable) |
|
Current consumption |
180 mA (when using a general-purpose I/O cable)*1 50 mA (when using an IO-Link cable) |
||
Display resolution | 0.1°C/°F | ||
Temperature unit | Celsius “°C”/Fahrenheit “°F” | ||
Measurement mode | Normal/Sample hold/Peak hold/Valley hold/Edge detection | ||
Response time (operating mode) |
High speed, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s Output response 90%*2 |
||
Analog output/ IO-Link update time |
High speed: 2.5 ms 50 ms to 2 s: 5.0 ms 5 s to 20 s: 100 ms |
||
Analog output |
Resolution | 10,801 steps | |
Accuracy | Voltage | ±0.2% of F.S. (at ambient temperature of 25°C) Temperature coefficient (typical): ±22 ppm/°C (±0.0022%/°C) |
|
Current | ±0.2% of F.S. (at ambient temperature of 25°C) Temperature coefficient (typical): ±4 ppm/°C (±0.0004%/°C) |
||
Indicator | Display | 1.8-inch TFT LCD Display language: English, Simplified Chinese, Japanese | |
Power indicator | When power is ON: lights in green, IO-Link communication: blinks in green | ||
Output indicator |
Normal measurement alarm output is OFF: lights green Normal measurement alarm output is ON: lights red When minor warning occurs: blinks green When major warning occurs: blinks orange When error occurs: blinks red |
||
Interface | Alarm output | NPN/PNP open collector (selectable by setting) 1 output: Max. 100 mA, 2 outputs: Max. 100 mA Residual voltage NPN: 1.6 V or less, PNP: 3.4 V or less |
|
Output mode | N.O./N.C. | ||
External input | Laser off, Hold, Trigger | ||
Analog output |
Current | 4 to 20 mA load impedance: 150 to 500 ohm | |
Voltage | 0 to 10 V output impedance: 200 ohm or less | ||
Timer mode | One shot/delay (ON delay, OFF delay) One shot: 0.01 to 10.00 sec, Delay: 0.00 to 10.00 sec |
||
IO-Link | Revision | 1.1.3 | |
Baud rate | COM 3 (230.4 kbps) | ||
Number of process input data bytes |
4 bytes | ||
Number of process output data bytes |
1 byte | ||
Minimum cycle time | 0.5 ms | ||
Data storage class | Data Storage Class 1: automatic DS | ||
Connection type |
General-purpose I/O cable |
3 m cable 9 wires, Minimum bending radius: R 42 mm | |
IO-Link cable |
Open-end | 3 m cable 3 wires, Minimum bending radius: R 42 mm | |
M12 4-pin connector |
0.3 m cable, Minimum bending radius: R 42 mm | ||
Environmental resistance |
Degree of protection | IP40 (IEC 60529) | |
Ambient temperature | 0 to +50°C | ||
Ambient humidity | 35 to 85% RH (no condensation) | ||
Storage temperature | −20 to +70°C | ||
Vibration resistance | 10 to 55 Hz Double amplitude 1.5 mm 2 hours in each X, Y, Z direction | ||
Shock resistance | 500 m/s2 (Approx. 50 G ) 3 times in each of the X,Y and Z directions | ||
Applicable regulations |
EMC | EMC Directive (2014/30/EU) UK EMC (The Electromagnetic Compatibility Regulations 2016) FCC Part 15 subpart B |
|
Environment | RoHS Directive (2011/65/EU) UK RoHS (The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012) China RoHS (MIIT Order No. 32) |
||
Applicable standards | EN/IEC 61326-1 | ||
Material | Case: ABS | ||
Weight | Approx. 80 g |
*1: Includes alarm output load current and analog output current.
*2: The response time is the time it takes for the output change to reach 90%.
* To convert temperature values such as measurement temperature range and accuracy to Fahrenheit temperature, use (Fahrenheit temperature = Celsius temperature x 1.8 + 32).
* To convert relative values such as repeatability and temperature drift to Fahrenheit temperatures, use 1°C = 1.8°F.
● Specifications are subject to change without prior notice.
Field of view(Unit: mm)
● The field of view is for a measurement diameter with an optical response (energy) of 90%.
● Size of the measurement target must be sufficiently larger than the field of view shown above.