IO-Link Compatible Non-Contact ThermometerTI-S Series

DOWNLOAD

High-Speed & High-Accuracy
Non-Contact Thermometer with Visible Field of View

  • Unique
    Technology

    Equipped with a ring laser pointer to improve work efficiency
  • First in
    Industry

    Measured temperature can be checked in a trend graph
  • Improved
    Performance

    High-accuracy measurement:
    ±1°C
    Response time:
    Achieves 50 ms or less
TI-S Series
  • Wide-ranging interface and measurement functions
  • Edge detection

    Detection of rapid temperature changes

    • Edge detection is provided, and detects when rapid temperature changes occurred.
      It is possible to only detect errors caused by temperature changes occurring within a short period of time.

  • Head internal temperature display

    • In addition to the temperature of the measurement target, the head internal temperature is also continuously displayed.
      This allows use while checking the effects of the ambient temperature.

  • Analog output

    For analog output, current output (4 to 20 mA) and voltage output (0 to 10 V) can be selected.
    It can be used without selecting an input device.

  • Best in class
    in industry

    Stable measurement with respect to ambient temperature fluctuations

    • Temperature measurement in heating and cooling processes often involves changes in the temperature at the installation environment.
      With the TI-S Series, stable continuous measurement is achieved compared with the previous model, even if the ambient temperature fluctuates.
      Temperature fluctuations of environment: Within ±0.25°C/°C

  • Alarm output (upper/lower limit settings)

    • A designated temperature range can be set as the threshold, and an alarm can be output when the measured temperature is outside of that range.

  • Bank function (4 channels)

    • 4 ch are installed for the bank function which can select (call) setting contents.
      The settings can be easily changed when the measurement condition changes.

  • First in Industry

    Trend graph

    • A trend graph of the measured temperature can be displayed covering up to 24 hours.

  • Maintenance alarm

    • Notification of maintenance timing can be provided when the preset period has elapsed for the timing of optical system cleaning, calibration, or other maintenance.

  • Hold display

    • Instead of displaying measured temperatures in real-time, you can hold display at the maximum or minimum temperatures during measurement.