IO-Link Compatible Non-Contact ThermometerTI-S Series

DOWNLOAD

Resistant to ambient temperature changes
Non-contact thermometer with ring laser pointer

  • Designed to be less susceptible to ambient temperature changes
  • Ring laser pointer for visual confirmation of field of view
  • Easy-to-read full color display
TI-S Series
High performance
  • High-accuracy measurement ±1°C

    Measurement can be performed with an accuracy of ±1°C. This thermometer can also meet stringent measurement requirements.
    * Measurement range: +1 to +200°C

  • High speed

    Achieves response times of 50 ms or less (high speed) with 90% response.
    So it is also effective for applications such as measuring the temperature of objects on a production line.
    Edge detection allows for immediate detection when rapid temperature changes occur.

 High accuracy and high speed

  •  Space-saving design allows installation anywhere and easy operation

  •  High-performance controller with color LCD in multiple languages

  • Wide-ranging interface and measurement functions
  • Edge detection

    Detection of rapid temperature changes

    • Edge detection is provided, and detects when rapid temperature changes occurred.
      It is possible to only detect errors caused by temperature changes occurring within a short period of time.

  • Head internal temperature display

    • In addition to the temperature of the measurement target, the head internal temperature is also continuously displayed.
      This allows use while checking the effects of the ambient temperature.

  • Analog output

    For analog output, current output (4 to 20 mA) and voltage output (0 to 10 V) can be selected.
    It can be used without selecting an input device.

  • Hold display

    • Instead of displaying measured temperatures in real-time, you can hold display at the maximum or minimum temperatures during measurement.

  • Alarm output (upper/lower limit settings)

    • A designated temperature range can be set as the threshold, and an alarm can be output when the measured temperature is outside of that range.

  • Bank function (4 channels)

    • 4 ch are installed for the bank function which can select (call) setting contents.
      The settings can be easily changed when the measurement condition changes.

  • First in Industry

    Trend graph

    • A trend graph of the measured temperature can be displayed covering up to 24 hours.

  • Maintenance alarm

    • Notification of maintenance timing can be provided when the preset period has elapsed for the timing of optical system cleaning, calibration, or other maintenance.