Digital Fiber AmplifiersD4RF Series

DOWNLOAD

Easy-to-Read, Easy-to-Use,
Digital Fiber Sensor Amplifiers with IO-Link supported

  • Easy-to-read OLED display
  • Fiber insertion indicators for instant verification
  • Large LED indicators for excellent visibility
  • Contributes to smart factories with IO-Link support
  • NEW MODELS

    Short-range/High accuracy type added to lineup
D4RF Series

Specifications

Type Stand-alone model
(IO-Link device)
Analog output
Model 1 output and
1 switchable
output/input*1
Cable D4RF-T
Connector D4RF-TC4
2 outputs and
1 input
Cable D4RF-TD / D4RF-TD-Y
Analog output Cable D4RF-TA / D4RF-TA-Y
Light source 4-element Red LED (Wavelength: 660 nm)
Response time 16 μs, 70 μs, 250 μs, 500 μs, 1 ms, 2 ms, 8 ms
Teach Mode 1 point, 2 points, Auto, Through, 1-point Zone, 2-point Zone, Manual Channel A (Analog output) setting: Analog 2 points teach, Analog auto teach, Manual
Channel 1 (Control output) setting: 1 point, 2 points, Auto, Through, 1-point Zone, 2-point Zone, Manual
Display Digital display OLED display 128 x 22 pixel
Menu languages: English, Japanese, Korean, Simplified Chinese, Spanish
Indicators 2 x Output indicator (orange),
Power indicator (green): Lights up when power is on (Blinks during IO-Link communication for stand-alone unit)
Control output indicator (orange), Analog output indicator (orange), Power indicator (green): Lights up when power is on
Interface Control output NPN/PNP open collector or Push-pull selectable by setting
1 output: Max. 100 mA,
2 outputs: Max. 50 mA /30 VDC residual voltage 1.8V or less
NPN/PNP open collector or Push-pull selecable by setting Max. 50 mA /30 VDC residual voltage 1.8 V or less
Analog output Current output: 4 to 20 mA, load impedance: 300 ohm or less
Voltage output: 0 to 10 V, 1 to 5 V, output impedance: 100 ohm or less
External input Teach, Counter-reset, Emitter off or Preset loading*2 Teach, Counter-reset, Emitter off, Hold out reset or Preset loading
IO-Link Control output 1 is switchable to IO-Link
IO-Link Revision 1.1
Baud rate COM 3 (230.4 kbps)
Number of process input data bytes 4 bytes
Minimum cycle time 0.5 ms
Timer function On delay, Off delay, On/off delay, Pulse output, On delay pulse, Adjustable 1 to 30,000 ms
Output mode Light ON/Dark ON, selectable by setting
Connection Cable type: 2m, 5 wires with 2-outputs and 1-input models, 4 wires with 1-output and 1-swichable-output/input models,
Minimum bending radius: 4 x Cable diameter
Connector type: M8 4-pin plug connector
Cable type: 2m, Minimum bending radius: 4 x Cable diameter
Insulation resistance 20 Megohm or more (with 500 VDC)
Rating Supply voltage SIO mode 12 to 30 VDC ± 10 %,
including 10 % ripple (p-p)
12 to 24 VDC ± 10 %,
including 10 % ripple (p-p)
IO-Link mode 18 to 30 VDC ± 10 %,
including 10 % ripple (p-p)
Current
consumption
Eco mode: Off 870 mW max. (29 mA or less at 30 VDC, 33 mA or less at 24 VDC, 52 mA or less at 12 VDC) 840 mW max. (35 mA or less at 24 VDC, 52 mA or less at 12 VDC)
Eco mode: On 780 mW max. (26 mA or less at 30 VDC, 29 mA or less at 24 VDC, 43 mA or less at 12 VDC) 744 mW max. (31 mA or less at 24 VDC, 43 mA or less at 12 VDC)
Warm-up time 300 ms
Applicable regulations EMC EU EMC directive (2014/30/EU) ,
UK directive EMC (The Electromagnetic Compatibility Regulations 2016)
Environment EU RoHS directive (2011/65/EU)
UK RoHS (The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012)
China RoHS (MIIT Order No.32)
Applicable standards EN 60947-5-2
NRTL certification UL Listed or Recognized Components
Proximity Switch Certified for US and Canada.
UL Recognized Component
Proximity Switch Certified for US and Canada.
Company standards Noise resistance Feilen Level 4 cleared
Protection circuit Reverse connection protection, Overcurrent protection
Environmental resistance Ambient temperature/humidity -25 to 55 °C/35 to 85 % RH (no freezing or condensation)
Ambient illuminance Sunlight: 10000 lx or less, Incandescent light: 3000 lx or less
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm; 2 hours in each of the X,Y and Z directions
Shock resistance Approx. 50 G (500 m/s2) 3 times in each of the X,Y and Z directions
Degree of protection IP54
Material Housing, cover: PC
Weight Cable model: approx. 71 g (including cable),
Connector model: approx. 25 g
Cable model: approx. 71 g (including cable)
Included items Mounting bracket, Instruction manual

*1: Input/output is not switchable for analog output.
*2: Preset loading selectable only on 2-outputs and 1-output models.

Type Standard inter-connection
With display and keys
Main unit Expansion unit
Model 1 output and
1 switchable
output/input
Cable D4RF-TM D4RF-TS
Connector D4RF-TMC4 D4RF-TSC4
2 outputs and
1 input
Cable D4RF-TDM / D4RF-TDM-Y D4RF-TDS / D4RF-TDS-Y
Light source 4-element Red LED (Wavelength: 660 nm)
Response time 16 μs, 70 μs, 250 μs, 500 μs,
1 ms, 2 ms, 8 ms
Teach Mode 1 point, 2 points, Auto, Through, 1-point Zone, 2-point Zone, Manual
Display Digital display OLED display 128 x 22 pixel
Menu languages: English, Japanese, Korean, Simplified Chinese, Spanish
Indicators 2 x Output indicator (orange), Power indicator (green): Lights up when power is on
Interface Control output*1 NPN/PNP open collector or Push-pull selectable by setting
1 output: Max. 100 mA, 2 output: Max. 50 mA/30 VDC residual voltage 1.8 V or less
External input Teach, Counter-reset, Emitter off or Preset loading*2
Number of units with cross talk prevention Response time 22 μs: 2 units, 70 μs: 3 units, 250 μs: 4 units, 500 μs: 9 units,1 ms: 9 units, 2ms: 12 units, 8 ms: 14 units (including main unit)
Timer function On delay, Off delay, On/off delay, Pulse output, On delay pulse, Adjustable 1 to 30,000 ms
Output mode Light ON/Dark ON, selectable by setting
Number of connectable units Max. 16 units (including main unit)
Connection Cable type: 2m,
Minimum bending radius: 4 x Cable diameter
5 wires with 2-outputs and 1-input main models,
4 wires with 1-output and 1-swichable-output/input main models,
3 wires with 2-outputs and 1-input expansion models,
2 wires with 1-output and 1-swichable output/input expansion models,
Connector type: M8 4-pin plug connector
Insulation resistance 20 Megohm or more (with 500 VDC)
Rating Supply voltage Supplied directly or from communication unit*3
12 to 24 VDC ±10 % including 10 % ripple (p-p)
Supplied from main unit or communication unit*3
12 to 24 VDC ±10 % including 10 % ripple (p-p)
Current
consumption*1
Eco mode: Off 792 mW max. (33 mA or less at 24 VDC, 52 mA or less at 12 VDC)
Eco mode: On 696 mW max. (29 mA or less at 24 VDC, 43 mA or less at 12 VDC)
Warm-up time 300 ms
Applicable regulations EMC EU EMC directive (2014/30/EU) ,
UK directive EMC (The Electromagnetic Compatibility Regulations 2016)
Environment EU RoHS directive (2011/65/EU)
UK RoHS (The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012)
China RoHS (MIIT Order No.32)
Applicable standards EN 60947-5-2
NRTL certification UL Listed or Recognized Components
Proximity Switch Certified for US and Canada.
Company standards Noise resistance Feilen Level 4 cleared
Protection circuit Reverse connection protection, Overcurrent protection
Environmental resistance Ambient temperature*4/humidity -25 to 55 °C/35 to 85 % RH (no freezing or condensation)
Ambient illuminance Sunlight: 10000 lx or less, Incandescent light: 3000 lx or less
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm; 2 hours in each of the X,Y and Z directions
Shock resistance Approx. 50 G (500 m/s2) 3 times in each of the X,Y and Z directions
Degree of protection IP54
Material Housing, cover: PC
Weight Cable model: approx. 71 g (including cable),
Connector model: approx. 25 g
Included items Mounting bracket, Instruction manual

*1: The load current and ambient temperature are limited by the number of connected units
      (including inter-connection main unit) as shown in the table below.
      Standard inter-connection use: 20 mA when connected with a 1-output setting or 10 mA with a 2-output setting.
*2: Preset loading is selectable only on 2-outputs and 1-output models.
*3: For details on supplying power from the communication unit, refer to the instruction manual of the respective
      communication unit.
*4: The upper ambient temperature limit is as follows depending on the number of connected units.
      3 to 5 connected units: 50 °C, 6 to 16 connected units: 45 °C (When used as UL certified product: 6 to
      8 connected units: 45 °C, 9 to 16 connected units: 40 °C)

Type Inter-connection for communication unit
With display and keys Without display and keys
Main unit Expansion unit Main unit Expansion unit
Model Without output/input wires Connector D4RF-MC4
Cable-less D4RF-TM-0 D4RF-TS-0 D4RF-S
Light source 4-element Red LED (Wavelength: 660nm)
Response time 22 μs、70 μs、250 μs、500 μs、1 ms、2 ms、8 ms
Teach Mode 1 point, 2 points, Auto, Through, 1-point Zone, 2-point Zone, Manual
Display Digital display OLED display 128 x 22 pixel
Menu languages: English, Japanese, Korean, Simplified Chinese, Spanish
Indicators 2 x Output indicator (orange),
Power indicator (green): Lights up when power is on
Number of units with cross talk prevention Response time 22 μs: 2 units, 70 μs: 3 units, 250 μs: 4 units, 500 μs: 9 units,1 ms: 9 units, 2ms: 12 units, 8 ms: 14 units (including main unit)
Timer function On delay, Off delay, On/off delay, Pulse output, On delay pulse, Adjustable 1 to 30,000 ms
Output mode Light ON/Dark ON, selectable by setting
Number of connectable units Max. 16 units (including main unit)
Connection Without cable or connector Connector type: M8 4-pin connector (For supplying power) Without cable or connector
Insulation resistance 20 Megohm or more (with 500 VDC)
Rating Supply voltage Supplied from communication unit*3
12 to 24 VDC ±10 % including 10 % ripple (p-p)
Supplied directly or from communication unit*3
12 to 24 VDC ±10 % including 10 % ripple (p-p)
Supplied from communication unit*3
12 to 24 VDC ±10 % including 10 % ripple (p-p)
Current
consumption*1
Eco mode: Off 720 mW max.
(30 mA or less at 24 VDC, 49 mA or less at 12 VDC)
624 mW max.
(26 mA or less at 24 VDC 41 mA or less at 12 VDC)
Eco mode: On 624 mW max.
(26 mA or less at 24 VDC 41 mA or less at 12 VDC)
Warm-up time 300 ms
Applicable regulations EMC EU EMC directive (2014/30/EU) ,
UK directive EMC (The Electromagnetic Compatibility Regulations 2016)
Environment EU RoHS directive (2011/65/EU)
UK RoHS (The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012)
China RoHS (MIIT Order No.32)
Applicable standards EN 60947-5-2
NRTL certification UL Listed or Recognized Components
Proximity Switch Certified for US and Canada.
Company standards Noise resistance Feilen Level 4 cleared
Protection circuit Reverse connection protection, Overcurrent protection
Environmental resistance Ambient temperature*4/humidity -25 to 55 °C/35 to 85 % RH (no freezing or condensation)
Ambient illuminance Sunlight: 10000 lx or less, Incandescent light: 3000 lx or less
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm;
2 hours in each of the X,Y and Z directions
Shock resistance Approx. 50 G (500 m/s2) 3 times in each of the X,Y and Z directions
Degree of protection IP54
Material Housing, cover: PC
Weight Approx. 23 g
Included items Mounting bracket, Instruction manual

*1: The load current and ambient temperature are limited by the number of connected units
      (including inter-connection main unit) as shown in the table below.
      Standard inter-connection use: 20 mA when connected with a 1-output setting or 10 mA with a 2-output setting.
*2: Preset loading is selectable only on 2-outputs and 1-output models.
*3: For details on supplying power from the communication unit, refer to the instruction manual of the respective
      communication unit.
*4: The upper ambient temperature limit is as follows depending on the number of connected units.
      3 to 5 connected units: 50 °C, 6 to 16 connected units: 45 °C (When used as UL certified product: 6 to
      8 connected units: 45 °C, 9 to 16 connected units: 40 °C)