Displacement Sensor AmplifiersCDA Series
Amplifier unit with English display
- Up to two displacement sensors can be connected
- Calculation of thickness, height difference, width, and more possible
- Equipped with analog and control outputs
Lineup
Type | Supported displacement sensor | Interface | Master/ slave unit |
Model |
---|---|---|---|---|
Displacement sensor amplifier unit |
•CDX series •TD1 series |
Analog output:1 4~20mA Control output:3 External input:2 |
Master | CDA-M |
Slave | CDA-S | |||
Control output:2 External input:1 |
Master |
• CDA-DM models have been discontinued. Please use the CDA-DM2 successor model. Click here for more information.
Specifications
Mode | Master unit | Slave unit | Master unit | |
---|---|---|---|---|
CDA-M | CDA-S | CDA-DM2 | ||
Displacement sensor |
No. of connectable units | Max. 2 units of CD22 or CDX or TD1 series (Connectable model of CD22 series: CD22-☐☐-485M12) |
||
Connection type | Amplifier side: M8, 4-pin connector / Sensor side: M12, 4-pin connector | |||
No. of connectable units (including master unit) |
Max. 8 units | |||
Rating | Supply voltage | 12 to 24 VDC ±10%, including 10% ripple (p-p) | ||
Current consumption | 100 mA or less (at 12 VDC) | 120 mA or less (at 12 V) | ||
Display | Dot matrix display | Organic EL panel 128 × 96 pixels | ||
Indicators | Power indicator: Red/Green, Output indicator : Orange | |||
Analog current output | No. of outputs | 1 output | 2 outputs | |
Type | 4 to 20 mA/F.S. Load impedance 300 Ω or less | 4 to 20 mA/F.S. Load impedance 300 Ω or less, 0 to 10 V output impedance 100 Ω (Switchable) |
||
Control output | No. of outputs | 3 outputs | 2 outputs | |
Type | NPN/PNP open collector , Max. 100 mA / 30 VDC, Residual voltage: 1.8 V or less |
|||
Output cycle | 500 μs | |||
External input | 2 inputs | 1 input | ||
Connection type | Cable type: Cable: 2 m (ø5.8) | |||
Environmental resistance |
Ambient temperature/humidity | -20 to +50℃ / 35 to 85% RH (no freezing or condensation) | ||
Storage temperature/humidity | -20 to +60℃ / 35 to 85% RH (no freezing or condensation) | |||
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance | Approximately 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions |
|||
Protection circuit | Reverse connection protection | |||
Degree of protection | IEC standard, IP50 | |||
Material | Polycarbonate | |||
Weight | 170 g |