Displacement Sensor AmplifiersCDA Series

DOWNLOAD

Amplifier unit with English display

  • Up to two displacement sensors can be connected
  • Calculation of thickness, height difference, width, and more possible
  • Equipped with analog and control outputs
CDA Series

Lineup

Type Compatible displacement sensors Interface Main/Expantion
unit
Model
Displacement
sensor
amplifier unit
CDX Series
CD22 Series
(RS-485 type)
TD1 Series
Analog output:1 4 to 20 mA
Control output:3
External input:2
Main CDA-M
Expantion CDA-S
Analog output:2 4 to 20 mA/0 to 0 V (selectable by setting)
Control output:2
External input:1
Main CDA-DM2

• CDA-DM models have been discontinued. Please use the CDA-DM2 successor model. Click here for more information.

Specifications

Type Analog output x 1 + external input x 2 Analog output x 2
Main unit Expansion unit Main unit
Model CDA-M CDA-S CDA-DM2
Compatible displacement sensors Supported models CDX Series
CD22 Series (RS-485 type)
TD1 Series
Number of
connectable units
Max. 2 units
Connection type Amplifier side: M8, 4-pin connector
Communication I/F RS-485 compliant (Overall cable length: Within 10m)
Rating Supply voltage 12 to 24 VDC ±10%, including 10% ripple (p-p)*1
Current consumption 100 mA or less (at 12 VDC) 120 mA or less (at 12 V)
Display Dot matrix display OLED 128 x 96 pixels
Indicators Power indicator: red/green, output indicator: orange
Analog output No. of outputs 1 1 2
Type 4 to 20 mA
Load impedance: 300 Ω or less
4 to 20 mA
Load impedance: 300 Ω or less
4 to 20 mA
Load impedance: 300 Ω or less
0 to 10 V
Output impedance: 100 Ω (selectable by setting)
Control output No. of outputs 3 3 2
Type NPN/PNP open collector (selectable by setting)
Max. 100 mA/30 VDC, Residual voltage: 1.8 V or less
Output cycle 500 μs
External input 2 2 1
Environmental
resistance
Ambient temperature/humidity -20 to +50℃ / 35 to 85% RH (no freezing or condensation)
Storage temperature/humidity -20 to +60℃ / 35 to 85% RH (no freezing or condensation)
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of the X, Y, and Z directions
Protection circuit Reverse connection protection
Degree of protection IP50
Applicable
regulations
EMC EMC directive (2014/108/EU)
Environment RoHS directive (2011/65/EU), China RoHS (Directive No. 32)
NRTL Certification UL Recognition
Material Polycarbonate
Weight 170 g

*1. Supply voltage of the expansion unit (CDA-S) is provided by the main unit.
      Supply 12 to 24 VDC to the power supply wires (brown and blue) of the cable as the power for the sensor heads.
• CDA-DM models have been discontinued. Please use CDA-DM2 successor model. Click here for more information.