Laser Displacement SensorsCD2H Series
Best-in-class*, All-in-one Middle-range Sensors
- Highest-in-class* Repeat Accuracy: 0.25 μm (CD2H-30□/CD2H-50□)
- Fastest-in-class* Sampling Period: 133.3 μs
- Measurement in a long distance up to 1,200 mm
- Received light waveform can be displayed on OLED Display.
- NEW MODELS Added six new RS-485 models
    
*Among laser displacement sensors with the repeat accuracy of 1 μm
(Investigated by OPTEX FA in November 2021)

I/O Circuit Diagrams
IO-Link/analog output Type
- 
	NPN setting*1 *1. When using NPN settings for an IO-Link connection, use OPTEX FA’s IO-Link Master UR Series or IO-Link Master with sink support. 
 *2. When used as control output DO1
 *3. When used as control output DO2
 *4. When used as analog output AO
- 
	PNP setting *1. When used as control output DO1 
 *2. When used as control output DO2
 *3. When used as analog output AO
- 
	Push-pull setting *1. When used as control output DO1 with NPN connection 
 *2. When used as control output DO2 with NPN connection
 *3. When used as control output DO1 with PNP connection
 *4. When used as control output DO2 with PNP connection
 *5. When used as analog output AO
- 
	M12 connector pin assignments 
RS-485 Type
- 
	NPN setting (when load is connected by
 NPN with the push-pull setting) *1. When used as control output 
 *2. When used as external input
 *3. Default setting for the termination resistor is ON.
 When multi-drop connections are made, turn the termination resistor OFF at all units except the unit which is connected at the end.
- 
	PNP setting (when load is connected by
 PNP with the push-pull setting) *1. When used as external input 
 *2. When used as control output
 *3. Default setting for the termination resistor is ON.
 When multi-drop connections are made, turn the termination resistor OFF at all units except the unit which is connected at the end.
- 
	6-wire twisted pair cable
 (CD-MC1206-G□S) 8-wire twisted pair cable for multi-drop
 (CD-MC1208-G□M) 
- 
	M12 connector pin assignments 
Dimensions
Sensor

Connector cables for IO-Link/analog output
- 
Standard cables
 YF2A15-020VB5XLEAX
 YF2A15-050VB5XLEAX
 YF2A15-100VB5XLEAXMinimum bending radius: 
 Cable diameter × 5 (when fixed in place) 
- 
Bending resistant cables
 DOL-1205-G02M-R
 DOL-1205-G05M-RMinimum bending radius: 
 Cable diameter × 2 (when fixed in place)
 Cable diameter × 6 (when movable) 
Connector cables for RS-485 communication
- 
6-wire twisted pair cable
 CD-MC1206-G2S
 CD-MC1206-G5SMinimum bending radius: 
 Cable diameter × 5 (when fixed in place)
 Cable diameter × 8 (when movable) 
- 
8-wire twisted pair cable for multi-drop
 CD-MC1208-G2M
 CD-MC1208-G5MMinimum bending radius: 
 Cable diameter × 5 (when fixed in place)
 Cable diameter × 8 (when movable) 
Mounting bracket
- 
BEF-WN-OD2000-B 