Laser Displacement SensorsCD2H Series
Best-in-class*, All-in-one Middle-range Sensors
- Highest-in-class* Repeat Accuracy: 0.25 μm (CD2H-30□/CD2H-50□)
- Fastest-in-class* Sampling Period: 133.3 μs
- Measurement in a long distance up to 1,200 mm
- Received light waveform can be displayed on OLED Display.
NEW MODELS
Added six new RS-485 models
*Among laser displacement sensors with the repeat accuracy of 1 μm
(Investigated by OPTEX FA in November 2021)

I/O Circuit Diagrams
IO-Link/analog output Type
-
NPN setting*1
*1. When using NPN settings for an IO-Link connection, use OPTEX FA’s IO-Link Master UR Series or IO-Link Master with sink support.
*2. When used as control output DO1
*3. When used as control output DO2
*4. When used as analog output AO -
PNP setting
*1. When used as control output DO1
*2. When used as control output DO2
*3. When used as analog output AO
-
Push-pull setting
*1. When used as control output DO1 with NPN connection
*2. When used as control output DO2 with NPN connection
*3. When used as control output DO1 with PNP connection
*4. When used as control output DO2 with PNP connection
*5. When used as analog output AO -
M12 connector pin assignments
RS-485 Type
-
NPN setting (when load is connected by
NPN with the push-pull setting)*1. When used as control output
*2. When used as external input
*3. Default setting for the termination resistor is ON.
When multi-drop connections are made, turn the termination resistor OFF at all units except the unit which is connected at the end. -
PNP setting (when load is connected by
PNP with the push-pull setting)*1. When used as external input
*2. When used as control output
*3. Default setting for the termination resistor is ON.
When multi-drop connections are made, turn the termination resistor OFF at all units except the unit which is connected at the end.
-
6-wire twisted pair cable
(CD-MC1206-G□S)8-wire twisted pair cable for multi-drop
(CD-MC1208-G□M) -
M12 connector pin assignments
Dimensions
Sensor

Connector cables for IO-Link/analog output
-
Standard cables
YF2A15-020VB5XLEAX
YF2A15-050VB5XLEAX
YF2A15-100VB5XLEAXMinimum bending radius:
Cable diameter × 5 (when fixed in place) -
Bending resistant cables
DOL-1205-G02M-R
DOL-1205-G05M-RMinimum bending radius:
Cable diameter × 2 (when fixed in place)
Cable diameter × 6 (when movable)
Connector cables for RS-485 communication
-
6-wire twisted pair cable
CD-MC1206-G2S
CD-MC1206-G5SMinimum bending radius:
Cable diameter × 5 (when fixed in place)
Cable diameter × 8 (when movable) -
8-wire twisted pair cable for multi-drop
CD-MC1208-G2M
CD-MC1208-G5MMinimum bending radius:
Cable diameter × 5 (when fixed in place)
Cable diameter × 8 (when movable)
Mounting bracket
-
BEF-WN-OD2000-B