M18 Cylindrical ThermometersSA-80 Series
Measurement temperature range: 0 to 200℃ / 0 to +400℃
- Easy installation and excellent environmental resistance
- High-speed response time of 100ms/90%
- IO-Link network supported (SA-80T-4IO)
- Wide field of view of φ80mm at 500mm
![SA-80 Series](/img/products/thermo/sa/prd_detail.png?r2)
Specifications
Model | SA-80T-2A | SA-80T-4A | SA-80T-4IO | |
---|---|---|---|---|
Measurement range |
0 to +200°C (32 to 392°F) | 0 to +400°C (32 to 752°F) | 0 to +400°C (32 to 752°F) | |
Field of view | ø80/500 mm | |||
Optics | Silicone lens | |||
Sensing element/ spectral response |
Thermopile/8 to 14 μm | |||
Response time | 100 ms/90% response | |||
Accuracy* | 0 to 200°C (32 to 392°F): ±2°C (±3.6°F), 201 to 400°C (393.8 to 752°F): ±1% of reading value * Measurement conditions: ε = 1.0, ambient temperature of 23 ± 5°C (73.4 ± 9°F), measurement distance of 250 mm, measurement target: ø100 mm |
|||
Repeatability | ±1°C (±1.8°F) | |||
Emissivity adjustment | 0.95 (fixed) | 0.1 to 1.2 | ||
Supply voltage | 12 to 24 VDC ± 10% | 18 to 30 VDC ± 10% | ||
Current consumption | Max. 70 mA | Max. 50 mA | ||
Communication interface | Not supported | IO-Link | ||
IO-Link specifications |
Minimum cycle time | − | − | 3 ms |
Communication speed | COM2 (38.4 kbps) | |||
IO-Link version | 1.1 | |||
Communication function operation power supply |
IO-Link power supply (supplied from IO-Link Master) |
|||
Process input data byte count |
4 bytes | |||
Process output data byte count |
0 byte | |||
Output | Analog output, 4 to 20 mA | Via IO-Link | ||
Total cable extension | − | 20 m | ||
Connection | 2 m cable | M12 4-pin 300 mm pigtail cable |
||
Environmental resistance |
Degree of protection | IP67 | ||
Ambient temperature | 0 to +70°C (32 to 158°F) | |||
Ambient humidity | 35 to 85%RH (no condensation) | |||
Storage temperature | −20 to +70°C (−4 to +158°F) | |||
Vibration resistance | 10 to 55 Hz, 1.5 mm amplitude, 2 hours each for XYZ directions | |||
Applicable regulations |
EMC | EMC Directive (2014/30/EU) | ||
Environment | RoHS Directive (2011/65/EU), China RoHS (MIIT Order No.32) | |||
Applicable standard | EN 61326-1:2013 | |||
Materials | SUS/AI | |||
Weight | Approx. 180 g | |||
Standard included accessories |
Mounting nut ×2 | Mounting nut × 2, Mounting bracket |
* With an environmental temperature of 23 ± 5°C (73.4 ± 9°F) and an environmental temperature fluctuation of ±1°C (±1.8°F)/hour and under Optex FA calibration conditions.
• Note that specifications are subject to change without prior notice for product improvement purposes.
Field of view
(Unit: mm)
The fields of view stated above are measurement diameters with an optical response of 90%.
The size of the measurement target must be sufficiently larger than the measurement diameters shown in the above diagram.