Digital Fiber SensorD2RF/D2GF Series

DOWNLOAD

Fiber amplifiers featuring dual outputs, dual displays, and dual sensitivity correction functions

D2RF/D2GF Series

Lineup

Type Shape Input/output Light source Degree of
protection
Model
(Models in parentheses are connector types)
NPN type PNP type
Inter-connection master
Control output: Dual output
(CH1 & CH2*)

Red
4 element
LED

IP50 D2RF-TMN
(D2RF-TMCN4)
D2RF-TMP
(D2RF-TMCP4)

Green LED

D2GF-TMN
(D2GF-TMCN4)
D2GF-TMP
(D2GF-TMCP4)
Inter-connection slave

Red
4 element
LED

D2RF-TSN
(D2RF-TSCN4)
D2RF-TSP
(D2RF-TSCP4)

Green LED

D2GF-TSN
(D2GF-TSCN4)
D2GF-TSP
(D2GF-TSCP4)
Stand-alone type

Red
4 element
LED

D2RF-TN
(D2RF-TCN4)
D2RF-TP
(D2RF-TCP4)

Green LED

D2GF-TN
(D2GF-TCN4)
D2GF-TP
(D2GF-TCP4)
Stand-alone type
Equipped with analog output
Control output: Single output
Analog output: 4 to 20 mA

Red
4 element
LED

D2RF-TAN D2RF-TAP
Water resistant stand-alone type
Control output: Dual output
(CH1 & CH2*)
IP66 D2RF-2TN
(D2RF-2TCN4)
D2RF-2TP
(D2RF-2TCP4)
Water resistant stand-alone type
Equipped with analog output
Control output: Single output
Analog output: 4 to 20 mA
D2RF-2TAN D2RF-2TAP

*CH2 can be switched to control output (CH2), alarm output, teach input, or counter reset input.
•For the connector type, please purchase an optional JCN series connector cable.

Specifications

Type Inter-connection master Inter-connection slave Stand-alone type Water resistant stand-alone type
Mode NPN Cable type D2RF-TMN D2RF-TSN D2RF-TN D2RF-2TN
Connector type D2RF-TMCN4 D2RF-TSCN4 D2RF-TCN4 D2RF-2TCN4
PNP Cable type D2RF-TMP D2RF-TSP D2RF-TP D2RF-2TP
Connector type D2RF-TMCP4 D2RF-TSCP4 D2RF-TCP4 D2RF-2TCP4
Light source 4 element red LED
Response time 60 μs (Fast mode) / 250 μs (Std mode) / 2 ms (Long mode)
Distance adjustment Teaching / manual adjustment
Indicators Output indicator (orange LED) × 2 (CH1/CH2)
Digital display 7-segment, 8-digit display (red: 4-digit, green: 4-digit)
Control output 2CH output*1 (CH1/CH2)
NPN/PNP open collector Max. 100 mA/30 VDC or less
Load current: 100 mA or less*2 Residual voltage: 1.8 V or less
(CH2 can be set for use as an alarm output)
Analog output -
Input settings Teach input*3 / counter reset input Selectable by setting
(using control output CH2)
Timer function OFF delay / ON delay / one-shot / no delay 1 to 9000 ms (adjustment is possible in 1 ms increments)
Output mode Light ON / Dark ON selectable by setting
Connectable units Up to 8 units -
Cross talk
prevention
No. of units
(including master unit)
Fast Unusable -
Std Up to 4 units -
Long Up to 4 units -
Connection type Cable type: Cable length: 2 m
(master unit: o3.8 mm, slave unit: o2.8 mm)
Connector type: M8, 4-pin
Insulation resistance 20 MΩ or more (with 500 VDC)
Rating Supply voltage 12 to 24 VDC, including 10% ripple (p-p)
Current consumption 45 mA or less / 24 V
Applicable regulations EMC directive (2004/108/EC)
Applicable standards EN 60947-5-2
Company standards Noise resistance: Feilen Level 3 cleared
Environmental resistance Ambient temperature/humidity -25 to +55℃*4 / 35 to 85% RH (no freezing or condensation)
Ambient illuminance Sunlight: 10000 lx or less Incandescent light: 3000 lx or less
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of the X, Y, and Z directions
Degree of protection IP50 IP66
Material Housing: PPE Cover: PC
Weight Cable type: Approx. 65 g (including cable)
Connector type: Approx. 25 g
Included accessories Mounting bracket
Type Inter-connection master Inter-connection slave Stand-alone type
Mode NPN Cable type D2GF-TMN D2GF-TSN D2GF-TN
Connector type D2GF-TMCN4 D2GF-TSCN4 D2GF-TCN4
PNP Cable type D2GF-TMP D2GF-TSP D2GF-TP
Connector type D2GF-TMCP4 D2GF-TSCP4 D2GF-TCP4
Light source Green LED
Response time 60 μs (Fast mode) / 250 μs (Std mode) / 2 ms (Long mode)
Distance adjustment Teaching / manual adjustment
Indicators Output indicator (orange LED) × 2 (CH1/CH2)
Digital display 7-segment, 8-digit display (red: 4-digit, green: 4-digit)
Control output 2CH output*1 (CH1/CH2)
NPN/PNP open collector Max. 100 mA/30 VDC or less
Load current: 100 mA or less*2 Residual voltage: 1.8 V or less
(CH2 can be set for use as an alarm output)
Analog output -
Input settings Teach input*3 / counter reset input Selectable by setting
(using control output CH2)
Timer function OFF delay / ON delay / one-shot / no delay 1 to 9000 ms (adjustment is possible in 1 ms increments)
Output mode Light ON / Dark ON selectable by setting
Connectable units Up to 8 units -
Cross talk
prevention
No. of units
(including master unit)
Fast Unusable -
Std Up to 4 units -
Long Up to 4 units -
Connection type Cable type: Cable length: 2 m
(master unit: o3.8 mm, slave unit: o2.8 mm)
Connector type: M8, 4-pin
Insulation resistance 20 MΩ or more (with 500 VDC)
Rating Supply voltage 12 to 24 VDC, including 10% ripple (p-p)
Current consumption 45 mA or less / 24 V
Applicable regulations EMC directive (2004/108/EC)
Applicable standards EN 60947-5-2
Company standards Noise resistance: Feilen Level 3 cleared
Environmental resistance Ambient temperature/humidity -25 to +55℃*4 / 35 to 85% RH (no freezing or condensation)
Ambient illuminance Sunlight: 10000 lx or less Incandescent light: 3000 lx or less
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of the X, Y, and Z directions
Degree of protection IP50
Material Housing: PPE Cover: PC
Weight Cable type: Approx. 65 g (including cable)
Connector type: Approx. 25 g
Included accessories Mounting bracket

•Specifications are subject to change without prior notice for product improvement purposes.
*1 Threshold adjustment/timer settings and Light ON/Dark ON switching can be set individually for CH1 and CH2.
*2 Total No. of connectable units when used stand-alone or including the master unit: 2 to 3 units. Please use an output current of 50 mA or less when linking a total of 4 to 8 units.
*3 Teaching mode from external input will be the mode performed in advance on the amplifier main unit (default: 1-point teaching).
*4 Total No. of connectable units when including the master unit: 1 to 3 (in the case of inter-connection types) Keep at -25 to +50℃ when linking a total of 4 to 8 units.

Type Equipped with stand-alone analog output Equipped with water resistant stand-alone analog output
Model NPN type D2RF-TAN D2RF-2TAN
PNP type D2RF-TAP D2RF-2TAP
Light source 4 element red LED
Response time 60 μs (Fast mode) / 250 μs (Std mode) / 2 ms (Long mode)
Distance adjustment Teaching / manual adjustment
Indicators Output indicator (orange LED)
Digital display 7-segment, 8-digit display (red: 4-digit, green: 4-digit)
Control output NPN/PNP open collector
Max. 100 mA/30 VDC or less
Load current: 100 mA or less
Residual voltage: 1.8 V or less
Analog output 4 to 20 mA Load impedance 300 Ω or less
Input settings -
Timer function OFF delay / ON delay / one-shot / no delay 1 to 9000 ms (adjustment is possible in 1 ms increments)
Output mode Light ON / Dark ON selectable by setting
Connectable units -
Cross talk
prevention
No. of units
(including master unit)
Fast -
Std -
Long -
Connection type Cable type: Cable length: 2 m, ø4 mm
Insulation resistance 20 MΩ or more (with 500 VDC)
Rating Supply voltage 12 to 24 VDC, including 10% ripple (p-p)
Current consumption 45 mA or less / 24 V
Applicable regulations EMC directive (2004/108/EC)
Applicable standards EN 60947-5-7
Company standards Noise resistance: Feilen Level 3 cleared
Environmental resistance Ambient temperature/humidity -25 to +55℃ / 35 to 85% RH (no freezing or condensation)
Ambient illuminance Sunlight: 10000 lx or less Incandescent light: 3000 lx or less
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of the X, Y, and Z directions
Degree of protection IP50 IP66
Material Housing: PPE Cover: PC
Weight Cable type: Approx. 65 g (including cable)
Connector type: Approx. 25 g
Included accessories Mounting bracket

•Specifications are subject to change without prior notice for product improvement purposes.