Universal Voltage LED BGS SensorsBGS-2V Series

DOWNLOAD

Standard BGS model A renewal of the BGS-V series

  • Dual lens achieves long range detection
  • Maximum sensing distance of 1 m
  • Universal voltage type that eliminates the need to choose power supply
BGS-2V Series

Lineup

Type Shape Type Sensing distance
(Adjustable distance range shown in parentheses)
Model
NPN type PNP type
BGS
model
DC power
BGS-2V30N
(BGS-2V30CN)
BGS-2V30P
(BGS-2V30CP)
BGS-2V50N
(BGS-2V50CN)
BGS-2V50P
(BGS-2V50CP)
BGS-2V100N
(BGS-2V100CN)
BGS-2V100P
(BGS-2V100CP)
Type Shape Type Sensing distance
(Adjustable distance range shown in parentheses)
Model
BGS
model
Universal
voltage
BGS-2V30
BGS-2V50
BGS-2V100

•For the connector type, please purchase an optional DOL-1204-G02M connector cable.

Specifications

DC power type

Type Short-range Mid-range Long-range
Model NPN Cable type BGS-2V30N BGS-2V50N BGS-2V100N
Connector type BGS-2V30CN BGS-2V50CN BGS-2V100CN
PNP Cable type BGS-2V30P BGS-2V50P BGS-2V100P
Connector type BGS-2V30CP BGS-2V50CP BGS-2V100CP
Sensing distance 10 to 300 mm*1 20 to 500 mm*1 20 to 1000 mm*1
Adjustable distance range 100 to 300 mm*1 150 to 500 mm*1 250 to 1000 mm*1
Light source Red LED
Response time 2 ms or less 3 ms or less
Hysteresis 5% or less 15% or less
Distance adjustment 2-turn potentiometer
Indicators Output indicator: Orange LED, Stability indicator: Green LED
Control output NPN/PNP type open collector Max. 100 mA/30 VDC
Output mode Light ON / Dark ON switched by wiring
Connection type Cable type: Cable length: 2 m, ø3.8 mm
Connector type: M12, 4-pin
Insulation resistance 20 MΩ or more (with 500 VDC)
Rating Supply voltage 10 to 30 VDC
Current consumption 35 mA or less
Applicable regulations EMC directive (2004/108/EC)
Applicable standards EN 60947-5-2
Company standards Noise resistance: Feilen Level 3 cleared
Environmental
resistance
Ambient temperature/humidity -25 to +55℃ (no freezing) / 35 to 85% RH (no condensation)
Ambient illuminance Sunlight: 10,000 lx Incandescent lamp: 3,000 lx
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of the X, Y, and Z directions
Degree of protection IEC standard, IP67
Material Housing: ABS (glass fiber filled, fire resistant),
Front cover: Polycarbonate
Weight without cable Approx. 50 g
Included accessories Mounting bracket: BEF-W250

*1. Using a 200 mm ☓ 200 mm white sheet of paper.
• Specifications are subject to change without prior notice for product improvement purposes.

Universal voltage type

Type Short-range Mid-range Long-range
Model Cable type BGS-2V30 BGS-2V50 BGS-2V100
Connector type - - -
Sensing distance 10 to 300 mm*1 20 to 500 mm*1 20 to 1000 mm*1
Adjustable distance range 100 to 300 mm*1 150 to 500 mm*1 250 to 1000 mm*1
Light source Red LED
Response time 15 ms or less
Hysteresis 5% or less 20% or less
Distance adjustment 2-turn potentiometer
Indicators Output indicator: Orange LED, Stability indicator: Green LED
Control output Relay × 1C*2 250 VAC/3 A or less,
30 VDC/2 A or less (load resistance)
Output mode Fixed to Light ON
Connection type Cable type: Cable length: 2 m, ø6.4 mm
Insulation resistance 20 MΩ or more (with 500 VDC)
Rating Supply voltage 24 to 240 VAC, 24 to 240 VDC
Current consumption 2.5 VA or less
Applicable regulations EMC directive (2004/108/EC), Low voltage directive (2006/95/EC)
Applicable standards EN 60947-5-2
Company standards Noise resistance: Feilen Level 3 cleared
Environmental
resistance
Ambient temperature/humidity -25 to +55℃ (no freezing) / 35 to 85% RH (no condensation)
Ambient illuminance Sunlight: 10,000 lx Incandescent lamp: 3,000 lx
Voltage resistance 2700 VAC / minute
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of the X, Y, and Z directions
Degree of protection IEC standard, IP67
Material Housing: ABS (glass fiber filled, fire resistant),
Front cover: Polycarbonate
Weight without cable Approx. 50 g
Included accessories Mounting bracket: BEF-W250

*1. Using a 200 mm ☓ 200 mm white sheet of paper.
*2. When driving the inductive load (with an induction valve, electromagnetic contactor, etc.) through the relay connection point, please use a noise absorption device (surge absorber).
• Specifications are subject to change without prior notice for product improvement purposes.
• Products certified for the Chinese CCC compulsory certification system also available. Please inquire for details.