Discontinued Models

Models

Type Measurement range Spot size Resolution Linearity Model
Diffuse mode Specular mode
Specular
reflection
Spot
ø30 μm 0.25 μm +/-0.05% of F.S. (+/-1 μm) CDX-L15A
Wide 30 × 1000 μm CDX-LW15A
Short
range
Spot
ø30 μm +/-0.03% of F.S. (+/-3 μm) +/-0.04% of F.S. (+/-2.4 μm) CDX-30A
Wide 30 × 1000 μm +/-0.015% of F.S. (+/-1.5 μm) CDX-W30A
Middle
range
Spot
ø70 μm Meas. range 65 to 85 mm:
+/-0.018% of F.S.(+/-7.2 μm)
Meas. range 85 to 105 mm:
+/-0.03% of F.S.(+/-12.0 μm)
+/-0.03%
of F.S.
(+/-6.0 μm)
CDX-85A
Wide 70 × 2000 μm +/-0.015% of F.S. (+/-6.0 μm) CDX-W85A
Long
range
Spot
ø120 μm Meas. range 110 to 150 mm:
+/-0.03% of F.S.(+/-24 μm)
Meas. range 150 to 190 mm:
+/-0.04% of F.S.(+/-32 μm)
CDX-150A
Wide 120 × 4000 μm +/-0.015% of F.S. (+/-12 μm) CDX-W150A

Regarding applicability of Export Trade Control Order enacted by Japanese government
for the CDX series

CautionCDX series sensor heads are products that are subject to “Export Trade Control Order Appended Table 1 2-(12) Measurement devices (including machine tools with a measurement function)”. Please inquire for details.

  • Low resolution models: Not applicable

    Model Measurement mode Resolution
    CDX-L15A Specular mode 0.25 μm
    CDX-LW15A
    CDX-30A Diffuse mode
    Specular mode
    CDX-W30A Diffuse mode
    Specular mode
    CDX-85A Diffuse mode
    Specular mode
    CDX-W85A Diffuse mode
    Specular mode
    CDX-150A Diffuse mode
    CDX-W150A
  • Standard models: Applicable

    Model Measurement mode Resolution
    CDX-L15 Specular mode 0.01 μm
    CDX-LW15
    CDX-30 Diffuse mode 0.05 μm
    Specular mode
    CDX-W30 Diffuse mode 0.05 μm
    Specular mode
    CDX-85 Diffuse mode 0.1 μm
    Specular mode
    CDX-W85 Diffuse mode 0.1 μm
    Specular mode
    CDX-150 Diffuse mode 0.2 μm
    CDX-W150

Attention: Not to be Used for Personnel Protection.

Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do not include the self-checking redundant circuitry necessary to allow their use in personnel safety applications.
A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Please consult our distributors about safety products which meet OSHA, ANSI and IEC standards for personnel protection.

● Specifications are subject to change without prior notice.

● Specifications and technical information not mentioned here are written in Instruction Manual. Or visit our website for details.

● All the warnings and cautions to know prior to use are given in Instruction Manual.