Discontinued Products
- Some models in this product series have been discontinued.
- Discontinued Models
Models
| Type | Measurement range | Spot size | Resolution | Linearity | Model | ||
|---|---|---|---|---|---|---|---|
| Diffuse mode | Specular mode | ||||||
| Specular reflection |
Spot |
![]() |
ø30 μm | 0.25 μm | — | +/-0.05% of F.S. (+/-1 μm) | CDX-L15A |
| Wide | 30 × 1000 μm | CDX-LW15A | |||||
| Short range |
Spot |
![]() |
ø30 μm | +/-0.03% of F.S. (+/-3 μm) | +/-0.04% of F.S. (+/-2.4 μm) | CDX-30A | |
| Wide | 30 × 1000 μm | +/-0.015% of F.S. (+/-1.5 μm) | CDX-W30A | ||||
| Middle range |
Spot |
![]() |
ø70 μm | Meas. range 65 to 85 mm: +/-0.018% of F.S.(+/-7.2 μm) Meas. range 85 to 105 mm: +/-0.03% of F.S.(+/-12.0 μm) |
+/-0.03% of F.S. (+/-6.0 μm) |
CDX-85A | |
| Wide | 70 × 2000 μm | +/-0.015% of F.S. (+/-6.0 μm) | CDX-W85A | ||||
| Long range |
Spot |
![]() |
ø120 μm | Meas. range 110 to 150 mm: +/-0.03% of F.S.(+/-24 μm) Meas. range 150 to 190 mm: +/-0.04% of F.S.(+/-32 μm) |
— | CDX-150A | |
| Wide | 120 × 4000 μm | +/-0.015% of F.S. (+/-12 μm) | CDX-W150A | ||||
Regarding applicability of Export Trade Control Order enacted by Japanese government
for the CDX series
CautionCDX series sensor heads are products that are subject to “Export Trade Control Order Appended Table 1 2-(12) Measurement devices (including machine tools with a measurement function)”. Please inquire for details.
-
Low resolution models: Not applicable
-
Standard models: Applicable
Model Measurement mode Resolution CDX-L15 Specular mode 0.01 μm CDX-LW15 CDX-30 Diffuse mode 0.05 μm Specular mode CDX-W30 Diffuse mode 0.05 μm Specular mode CDX-85 Diffuse mode 0.1 μm Specular mode CDX-W85 Diffuse mode 0.1 μm Specular mode CDX-150 Diffuse mode 0.2 μm CDX-W150
Attention: Not to be Used for Personnel Protection.
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do not include the self-checking redundant circuitry necessary to allow their use in personnel safety applications.
A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Please consult our distributors about safety products which meet OSHA, ANSI and IEC standards for personnel protection.
● Specifications are subject to change without prior notice.
● Specifications and technical information not mentioned here are written in Instruction Manual. Or visit our website for details.
● All the warnings and cautions to know prior to use are given in Instruction Manual.