Downloads

Specifications

Technical Data

Type Stand-alone Master connection Slave connection
Model NPN D3WF-TN D3WF-TMCN4 D3WF-TSCN4
PNP D3WF-TP D3WF-TMCP4 D3WF-TSCP4
Light source White LED
Response time High: 16μs*1, Standard: 200 μs
Sensitivity adjustment Teaching and manual adjustments
Indicators Output indicator (orange)
Digital display 7-segment, 8-digit display (red: 4-digit, green: 4-digit)
Control output 1 ch, NPN/PNP open collector max. 100 mA*2/
30 VDC, residual voltage: 1.8 V or less
External input Teaching input,*3 all teaching input, output mode selection,
control output OFF, input OFF
Cross talk prevention ON/OFF switchable, up to 3 units
Timer function ON delay, OFF delay, one-shot, ON+OFF delay,
ON+one-shot settable to 0.1 to 9999 ms
Output mode Light ON/Dark ON, set automatically during teaching,
switched with external input and the settings
No. of connectable units Max. 16 (including master unit)
Connection type 2m cable M8 4-pin connector
Insulation resistance 20 MΩ or more (with 500 VDC)
Rating Supply voltage 12 to 24 VDC ±10%,including10%ripple(p-p)
Power consumption
(normally)
864mW (36 mA or less at 24 V)
Power consumption
(Eco ALL)
720 mW (30 mA or less at 24 V)
Warm-up time 300ms
Applicable
regulations
EMC EMC directive (2014/30/EU)
Environment RoHS directive (2011/65/EU), China RoHS (MIIT Order No. 32)
Applicable standards EN 60947-5-2
Company standards Noise resistance: Feilen Level 3 cleare
Photobiological safety Risk group 2 (IEC 62471/JIS C 7550)
Environmental resistance Ambient temperature/humidity −25 to +55°C*4/35 to 85%RH (no freezing or condensation)
Ambient illuminance Sunlight: 10000 lx or less, Incandescent light: 3000 lx or less
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm;
2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s2),
3 times in each of tde X, Y, and Z directions
Protection circuit Reverse connection protection, overcurrent protection
Degree of protection IP50
Material Housing, cover: PC
Weight Approx. 71 g
(Including cable)
Approx. 25 g
Included accessories Mounting bracket

*1: The response time is 32 μs when master/slave connection units are linked with the cross talk prevention function on.
*2: When used as a stand-alone unit or when the number of inter-connected units includ-ing the master unit is 2 or 3.
Use a load current of 50 mA or less for 4 to 8 units and 20 mA or less for 9 to16 units.
*3: Teaching mode from external input is a mode executed in advance by the main unit (default: dynamic teaching).
*4: When used as a stand-alone unit or when the number of inter-connected units includ-ing the master unit is 2 or 3.
Keep at −25 to +50°C for 4 to 8 units and −25 to +45°C for 9 to 16 units.