Discontinued Products
For suitable alternatives, please feel free to contact us.
Specifications
Technical Data
| Type | Stand-alone type | Inter-connection master | Inter-connection slave | Water detection | |||
|---|---|---|---|---|---|---|---|
| Mode | NPN | Single output |
Cable type | D3RF-TN | D3RF-TMN | D3RF-TSN | D3IF-TN |
| Connector type | D3RF-TCN4 | D3RF-TMCN4 | D3RF-TSCN4 | D3IF-TCN4 | |||
| Dual output | Cable type | D3RF-TDN | D3RF-TDMN | D3RF-TDSN | - | ||
| PNP | Single output |
Cable type | D3RF-TP | D3RF-TMP | D3RF-TSP | D3IF-TP | |
| Connector type | D3RF-TCP4 | D3RF-TMCP4 | D3RF-TSCP4 | D3IF-TCP4 | |||
| Dual output | Cable type | D3RF-TDP | D3RF-TDMP | D3RF-TDSP | - | ||
| Light source | 4 element red LED (wavelengtd 632 nm) | Infrared LED (wavelengtd 1.45 μm) | |||||
| Response time *1 |
1-HS mode | 16 μs | 16 μs (when linked 22 μs) | 22 μs | 16 μs | ||
| 2-FS mode | 70 μs | 70 μs (when linked 85 μs) | 85 μs | 70 μs | |||
| 3-ST mode | 250 μs | ||||||
| 4-LG mode | 500 μs | ||||||
| 5-PL mode | 1 ms | ||||||
| 6-UL mode | 2 ms | ||||||
| 7-EL mode | 8 ms | ||||||
| Distance adjustment | Various types of teaching and manual adjustment | ||||||
| Indicators | Single output type: Output indicator (orange) Dual output type: Output indicator (orange) ×2 |
||||||
| Digital display | 7-segment, 8-digit display (red: 4-digit, green: 4-digit) | ||||||
| Control output*2 | NPN/PNP open collector Max. 100 mA*3/30 VDC, residual voltage: 1.8 V or less |
||||||
| External input | Teach input*4, Test input, synchronous input, counter reset input*5 | ||||||
| Timer function | ON delay, OFF delay, one-shot, ON + OFF delay, ON + one-shot settable 0.1 to 9999 ms |
||||||
| Output mode | Light ON / Dark ON selectable by setting | ||||||
| No. of connectable units (including master unit) |
Max. 16 units | ||||||
| Connection type | Cable type: Cable length: 2 m Connector type: M8, 4-pin | ||||||
| Insulation resistance | 20 MΩ or more (with 500 VDC) | ||||||
| Rating | Supply voltage | 12 to 24 VDC ±10%, including 10% ripple (p-p) | |||||
| Power consumption (normally) |
Single output type: 864 mW (36 mA or less at 24 V) Dual output type: 936 mW (39 mA or less at 24 V) |
||||||
| Power consumption (Eco ALL) |
Single output type: 600 mW (25 mA or less at 24 V) Dual output type: 672 mW (28 mA or less at 24 V) |
||||||
| Applicable regulations | EMC directive (2004/108/EC) | ||||||
| Applicable standards | EN 60947-5-2 | ||||||
| Company standards | Noise resistance: Feilen Level 4 cleared | ||||||
| Environmental resistance | Ambient temperature/humidity | -25 to +55℃*6 / 35 to 85% RH (no freezing or condensation) | |||||
| Ambient illuminance | Sunlight: 10000 lx or less Incandescent light: 3000 lx or less | ||||||
| Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of tde X, Y, and Z directions |
||||||
| Shock resistance | Approx. 50 G (500 m/s2), 3 times in each of tde X, Y, and Z directions |
||||||
| Degree of protection | IP50 | ||||||
| Material | Housing, cover: PC | ||||||
| Weight | Cable type: Approx. 71 g / Connector type: Approx. 25 g | ||||||
| Included accessories | Mounting bracket | ||||||
•Specifications are subject to change without prior notice for product improvement purposes.
*1 When Eco mode is set to rESP or ALL, the response time is doubled.
*2 For dual output types, the threshold value/timer and Light ON/Dark ON can be set individually for output 1 and output 2. Additionally,ASC is only available for output 1.
*3 No. of connectable units when used stand-alone or as the master unit: 2 to 3 units. Please use a load current of 50 mA or less for 4 to 8 units, and 20 mA or less for 9 to 16 units.
*4 Teaching mode from external input is a mode executed in advance by the main unit (default: 2-point teaching).
*5 The counter function is a function only for the dual output type, as counter reset input is not equipped to single output types.
*6 No. of connectable units when used stand-alone or as the master unit: 2 to 3 units. Keep at -25 to +50°C for 4 to 8 units, and -25 to +45℃ for 9 to 16 units.