Specifications
Technical Data
| Type | Inter-connection master | Inter-connection slave | Stand-alone type | Water resistant stand-alone type | ||
|---|---|---|---|---|---|---|
| Mode | NPN | Cable type | D2RF-TMN | D2RF-TSN | D2RF-TN | D2RF-2TN |
| Connector type | D2RF-TMCN4 | D2RF-TSCN4 | D2RF-TCN4 | D2RF-2TCN4 | ||
| PNP | Cable type | D2RF-TMP | D2RF-TSP | D2RF-TP | D2RF-2TP | |
| Connector type | D2RF-TMCP4 | D2RF-TSCP4 | D2RF-TCP4 | D2RF-2TCP4 | ||
| Light source | 4 element red LED | |||||
| Response time | 60 μs (Fast mode) / 250 μs (Std mode) / 2 ms (Long mode) | |||||
| Distance adjustment | Teaching / manual adjustment | |||||
| Indicators | Output indicator (orange LED) × 2 (CH1/CH2) | |||||
| Digital display | 7-segment, 8-digit display (red: 4-digit, green: 4-digit) | |||||
| Control output | 2CH output*1 (CH1/CH2) NPN/PNP open collector Max. 100 mA/30 VDC or less Load current: 100 mA or less*2 Residual voltage: 1.8 V or less (CH2 can be set for use as an alarm output) |
|||||
| Analog output | - | |||||
| Input settings | Teach input*3 / counter reset input Selectable by setting (using control output CH2) |
|||||
| Timer function | OFF delay / ON delay / one-shot / no delay 1 to 9000 ms (adjustment is possible in 1 ms increments) | |||||
| Output mode | Light ON / Dark ON selectable by setting | |||||
| Connectable units | Up to 8 units | - | ||||
| Cross talk prevention No. of units (including master unit) |
Fast | Unusable | - | |||
| Std | Up to 4 units | - | ||||
| Long | Up to 4 units | - | ||||
| Connection type | Cable type: Cable length: 2 m (master unit: o3.8 mm, slave unit: o2.8 mm) Connector type: M8, 4-pin |
|||||
| Insulation resistance | 20 MΩ or more (with 500 VDC) | |||||
| Rating | Supply voltage | 12 to 24 VDC, including 10% ripple (p-p) | ||||
| Current consumption | 45 mA or less / 24 V | |||||
| Applicable regulations | EMC directive (2004/108/EC) | |||||
| Applicable standards | EN 60947-5-2 | |||||
| Company standards | Noise resistance: Feilen Level 3 cleared | |||||
| Environmental resistance | Ambient temperature/humidity | -25 to +55℃*4 / 35 to 85% RH (no freezing or condensation) | ||||
| Ambient illuminance | Sunlight: 10000 lx or less Incandescent light: 3000 lx or less | |||||
| Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions |
|||||
| Shock resistance | Approx. 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions |
|||||
| Degree of protection | IP50 | IP66 | ||||
| Material | Housing: PPE Cover: PC | |||||
| Weight | Cable type: Approx. 65 g (including cable) Connector type: Approx. 25 g |
|||||
| Included accessories | Mounting bracket | |||||
| Type | Inter-connection master | Inter-connection slave | Stand-alone type | ||
|---|---|---|---|---|---|
| Mode | NPN | Cable type | D2GF-TMN | D2GF-TSN | D2GF-TN |
| Connector type | D2GF-TMCN4 | D2GF-TSCN4 | D2GF-TCN4 | ||
| PNP | Cable type | D2GF-TMP | D2GF-TSP | D2GF-TP | |
| Connector type | D2GF-TMCP4 | D2GF-TSCP4 | D2GF-TCP4 | ||
| Light source | Green LED | ||||
| Response time | 60 μs (Fast mode) / 250 μs (Std mode) / 2 ms (Long mode) | ||||
| Distance adjustment | Teaching / manual adjustment | ||||
| Indicators | Output indicator (orange LED) × 2 (CH1/CH2) | ||||
| Digital display | 7-segment, 8-digit display (red: 4-digit, green: 4-digit) | ||||
| Control output | 2CH output*1 (CH1/CH2) NPN/PNP open collector Max. 100 mA/30 VDC or less Load current: 100 mA or less*2 Residual voltage: 1.8 V or less (CH2 can be set for use as an alarm output) |
||||
| Analog output | - | ||||
| Input settings | Teach input*3 / counter reset input Selectable by setting (using control output CH2) |
||||
| Timer function | OFF delay / ON delay / one-shot / no delay 1 to 9000 ms (adjustment is possible in 1 ms increments) | ||||
| Output mode | Light ON / Dark ON selectable by setting | ||||
| Connectable units | Up to 8 units | - | |||
| Cross talk prevention No. of units (including master unit) |
Fast | Unusable | - | ||
| Std | Up to 4 units | - | |||
| Long | Up to 4 units | - | |||
| Connection type | Cable type: Cable length: 2 m (master unit: o3.8 mm, slave unit: o2.8 mm) Connector type: M8, 4-pin |
||||
| Insulation resistance | 20 MΩ or more (with 500 VDC) | ||||
| Rating | Supply voltage | 12 to 24 VDC, including 10% ripple (p-p) | |||
| Current consumption | 45 mA or less / 24 V | ||||
| Applicable regulations | EMC directive (2004/108/EC) | ||||
| Applicable standards | EN 60947-5-2 | ||||
| Company standards | Noise resistance: Feilen Level 3 cleared | ||||
| Environmental resistance | Ambient temperature/humidity | -25 to +55℃*4 / 35 to 85% RH (no freezing or condensation) | |||
| Ambient illuminance | Sunlight: 10000 lx or less Incandescent light: 3000 lx or less | ||||
| Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions |
||||
| Shock resistance | Approx. 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions |
||||
| Degree of protection | IP50 | ||||
| Material | Housing: PPE Cover: PC | ||||
| Weight | Cable type: Approx. 65 g (including cable) Connector type: Approx. 25 g |
||||
| Included accessories | Mounting bracket | ||||
•Specifications are subject to change without prior notice for product improvement purposes.
*1 Threshold adjustment/timer settings and Light ON/Dark ON switching can be set individually for CH1 and CH2.
*2 Total No. of connectable units when used stand-alone or including the master unit: 2 to 3 units. Please use an output current of 50 mA or less when linking a total of 4 to 8 units.
*3 Teaching mode from external input will be the mode performed in advance on the amplifier main unit (default: 1-point teaching).
*4 Total No. of connectable units when including the master unit: 1 to 3 (in the case of inter-connection types) Keep at -25 to +50℃ when linking a total of 4 to 8 units.
| Type | Equipped with stand-alone analog output | Equipped with water resistant stand-alone analog output | |
|---|---|---|---|
| Model | NPN type | D2RF-TAN | D2RF-2TAN |
| PNP type | D2RF-TAP | D2RF-2TAP | |
| Light source | 4 element red LED | ||
| Response time | 60 μs (Fast mode) / 250 μs (Std mode) / 2 ms (Long mode) | ||
| Distance adjustment | Teaching / manual adjustment | ||
| Indicators | Output indicator (orange LED) | ||
| Digital display | 7-segment, 8-digit display (red: 4-digit, green: 4-digit) | ||
| Control output | NPN/PNP open collector Max. 100 mA/30 VDC or less Load current: 100 mA or less Residual voltage: 1.8 V or less |
||
| Analog output | 4 to 20 mA Load impedance 300 Ω or less | ||
| Input settings | - | ||
| Timer function | OFF delay / ON delay / one-shot / no delay 1 to 9000 ms (adjustment is possible in 1 ms increments) | ||
| Output mode | Light ON / Dark ON selectable by setting | ||
| Connectable units | - | ||
| Cross talk prevention No. of units (including master unit) |
Fast | - | |
| Std | - | ||
| Long | - | ||
| Connection type | Cable type: Cable length: 2 m, ø4 mm | ||
| Insulation resistance | 20 MΩ or more (with 500 VDC) | ||
| Rating | Supply voltage | 12 to 24 VDC, including 10% ripple (p-p) | |
| Current consumption | 45 mA or less / 24 V | ||
| Applicable regulations | EMC directive (2004/108/EC) | ||
| Applicable standards | EN 60947-5-7 | ||
| Company standards | Noise resistance: Feilen Level 3 cleared | ||
| Environmental resistance | Ambient temperature/humidity | -25 to +55℃ / 35 to 85% RH (no freezing or condensation) | |
| Ambient illuminance | Sunlight: 10000 lx or less Incandescent light: 3000 lx or less | ||
| Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions |
||
| Shock resistance | Approx. 50 G (500 m/s2), 3 times in each of the X, Y, and Z directions |
||
| Degree of protection | IP50 | IP66 | |
| Material | Housing: PPE Cover: PC | ||
| Weight | Cable type: Approx. 65 g (including cable) Connector type: Approx. 25 g |
||
| Included accessories | Mounting bracket | ||