Specifications
CD5 series
  Sensor heads
 
Narrow spot type FDA CLASS II CD5-30 CD5-85
Wide spot type FDA CLASS II CD5-W30 CD5-W85 CD5-W350 CD5-W500
Measuring Range 30+/-5mm 85+/-20mm 350+/-100mm 500+/-200mm
Light Source (Narrow spot type) Red Semiconductor laser, 650nm, Max 1mW
  (Wide spot type) Red Semiconductor laser, 658nm, Max 1mW
Spot size (*1) (Narrow spot type) 30 x 100μm 70 x 290μm
  (Wide spot type) 260 x 1000μm 260 x 1200μm 700 x 2400μm 1000 x 3700μm
Linearity (*2) ±0.08%F.S. (F.S.=10mm) ±0.05%F.S. (F.S.=40mm) ±0.08%F.S. (F.S.=200mm) ±0.08%F.S. (F.S.=400mm)
Resolution (*2) 0.2μm 1μm 5μm 10μm
Sampling period (*3) 100, 200, 400, 800, 1600, 3200μs
Temperature Drift (*4) ±0.01%F.S./(F.S.=10mm) ±0.01%F.S./(F.S.=40mm) ±0.01%F.S./(F.S.=200mm) ±0.01%F.S./(F.S.=400mm)
Serial I/F (*5) RS-422 9.6k ~ 1843.2kbps
Power Supply DC12 ~ 24V ±10% or from CD5A-N/P Controller
Power Consumption Max. 45mA (DC24V)
Indicator LED (Laser) Green = Laser is active
  (Measurement) Orange = Within ±5% of measurement distance center
Red = Near side within measurement range
Green = Far side within measurement range
Red/Green alternately = Out of measurement range
Protection Category IP67
Operating Temperature / Humidity -10 to 50 35 to 85% RH (without condensing)
Storage Temperature / Humidity -20 to 60 35 to 85% RH (without condensing)
Ambient illuminance Incandescent Lamp = Max. 3,000 lux (incandescent lamp)
Vibration Resistance 10 to 55 Hz / 1.5mm for XYZ 2hours
Shock Resistance 50G (500m/s2) XYZ 3times
Cable Extendible up to 50m by extension cable
Extension cable DSL-1212-G02M (2m), DSL-1212-G05M (5m)
Material Case: Aluminum diecast
Weight Approx. 250g including 500mm cable
 
Condition for this specification:
 Temperature: 23, Power supply: 24VDC, Sampling period: 100μs (CD5-W350/-W500/-W2000: 800μs)
 No. of averaging times: 256, Target object: Aluminum vapor deposition Mirror (specular type), White ceramic (diffuse type)

*1  Defined at center strength 1/e2 (13.5%). There may be leak light other than the spot size.
The sensor may be affected when there is a highly reflective object close to the detection area.
*2  No. of averaging times: 4096
*3  Default: CD5-(W)30/-(W)85: 100μs, CD5-W350/-W500: 800μs
*4  Typical data
*5  Without controller. Default setting is 9.6kbps, Following is I/F speed without any missing data.
100μs: 921.6kbps, 200μs: 460.8kbps, 400μs: 230.4kbps, 800μs: 115.2kbps, 1600μs: 57.6kbps, 3200μs: 38.4kbps
 
  Sensor head (Specular Type)
 
Product Type CD5-L25 CD5-LW25
Measuring Range 25+/-1mm
Light Source FDA CLASS II Red Semiconductor laser 650nm, Max 0.39mW
Spot Size (*1) 25 x 35μm 100 x 700μm
Linearity (*2) ±0.08%F.S. (F.S.=2mm)
Resolution (*2) 0.02μm
Sampling period (*3) 100, 200, 400, 800, 1600, 3200μs
Temperature Drift (*4) ±0.01% F.S./ (F.S.=2mm) ±0.05% F.S./ (F.S.=2mm)
Serial I/F (*5) RS-422 9.6k ~ 1843.2kbps
Power Supply DC12 ~ 24V ±10% or from CD5A-N/P Controller
Power Consumption Max. 45mA (DC24V)
Indicator LED (Laser) Green = Laser is active
  (Measurement) Orange = Within ±5% of measurement distance center
Red = Near side within measurement range
Green = Far side within measurement range
Red/Green alternately = Out of measurement range
Protection Category IP67
Operating Temperature / Humidity -10 to 50 35 to 85% RH (without condensing)
Storage Temperature / Humidity -20 to 60 35 to 85% RH (without condensing)
Ambient illuminance Incandescent Lamp = Max. 3,000 lux (incandescent lamp)
Vibration Resistance 10 to 55 Hz / 1.5mm for XYZ 2hours
Shock Resistance 50G (500m/s2) XYZ 3times
Cable Extendible up to 50m by extension cable
Extension cable DSL-1212-G02M (2m), DSL-1212-G05M (5m)
Material Case: Aluminum diecast
Weight Approx. 250g including 500mm cable
 
Condition for this specification:
 Temperature: 23, Power supply: 24VDC
 No. of averaging times: 256, Target object: Aluminum vapor deposition Mirror (specular type)

*1  Defined at center strength 1/e2 (13.5%). There may be leak light other than the spot size.
The sensor may be affected when there is a highly reflective object close to the detection area.
*2  No. of averaging times: 4096
*3  Default: 100μs
*4  Typical data
*5  Without controller. Default setting is 9.6kbps, Following is I/F speed without any missing data.
100μs: 921.6kbps, 200μs: 460.8kbps, 400μs: 230.4kbps, 800μs: 115.2kbps, 1600μs: 57.6kbps, 3200μs: 38.4kbps
 
  Sensor head (Ultra long range Type)
 
Product Type CD5-W2000
Measuring Range 2000+/-500mm
Light Source FDA CLASS IIIa Red Semiconductor laser 658nm, Max 5mW
Spot Size (*1) 2100 x 7800μm
Linearity (*2) ±0.1%F.S. (F.S.=1000mm)
Resolution (*2) 30μm
Sampling period (*3) 100, 200, 400, 800, 1600, 3200μs
Temperature Drift (*4) ±0.05% F.S./ (F.S.=1000mm)
Serial I/F (*5) RS-422 9.6k ~ 1843.2kbps
Power Supply DC12 ~ 24V ±10% or from CD5A-N/P Controller
Power Consumption Max. 45mA (DC24V)
Indicator LED (Laser) Green = Laser is active
  (Measurement) Orange = Within ±5% of measurement distance center
Red = Near side within measurement range
Green = Far side within measurement range
Red/Green alternately = Out of measurement range
Protection Category IP67
Operating Temperature / Humidity -10 to 50 35 to 85% RH (without condensing)
Storage Temperature / Humidity -20 to 60 35 to 85% RH (without condensing)
Ambient illuminance Incandescent Lamp = Max. 3,000 lux (incandescent lamp)
Vibration Resistance 10 to 55 Hz / 1.5mm for XYZ 2hours
Shock Resistance 50G (500m/s2) XYZ 3times
Cable Extendible up to 50m by extension cable
Extension cable DSL-1212-G02M (2m), DSL-1212-G05M (5m)
Material Case: Aluminum diecast
Weight Approx. 450g including 500mm cable
 
Condition for this specification:
 Temperature: 23, Power supply: 24VDC, Sampling period: 800μs
 No. of averaging times: 256, Target object: White ceramic (diffuse type)

*1  Defined at center strength 1/e2 (13.5%). There may be leak light other than the spot size.
The sensor may be affected when there is a highly reflective object close to the detection area.
*2  No. of averaging times: 4096
*3  Default: 800μs
*4  Typical data
*5  Without controller. Default setting is 9.6kbps, Following is I/F speed without any missing data.
100μs: 921.6kbps, 200μs: 460.8kbps, 400μs: 230.4kbps, 800μs: 115.2kbps, 1600μs: 57.6kbps, 3200μs: 38.4kbps
 
  Amplifier Specification
 
Model CD5A-N (NPN output type) CD5A-P (PNP output type)
Number of connectable sensor heads Max. 3
Power Supply DC 12 to 24V ±10%
Power consumption 350 mA/24V
Temperature drift ±0.01% F.S./
Interface RS-232C/USB
Analog output Voltage output: ±10V/F.S. (output impedance 100 Ω), Current output: 4 to 20 mA/F.S. (Load impedance 300 Ω)
Alarm output NPN/PNP open collector, Max.100mA/DC24V (Residual Voltage: Max.1.8V), ON when the controller had problem
Control output NPN/PNP open collector, Max.100mA/DC24V (Residual Voltage: Max.1.8V)
Bank input ON when connected to GND, 16 banks are selectable
Hold input ON when connected to GND
Zero reset input ON when connected to GND, Measurement value and calculated result can be reset
Laser OFF input ON when connected to GND
Display 4.3" TFT LCD display
Protection category IP20
Operating Temperature / Humidity -10 to 45 35 to 85% RH (without condensing)
Storage Temperature / Humidity -20 to 60 35 to 85% RH (without condensing)
Vibration resistance 10 to 55 Hz / 1.5mm, XYZ 2hours
Shock resistance 20G (196m/s2) XYZ 3times
Material Case: Polycarbonate, Connection terminals: Nylon 66
Weight 550g including connection terminals
 