Specifications
CD4 series
  Sensor heads
 
IEC Class 1(FDA Class II) Type CD4-30 CD4-85 CD4-350
High power Class 3R Type CD4-30-3R CD4-85-3R CD4-350-3R
Measuring Range 30+/-5mm 85+/-20mm 350+/-100mm
Light Source (Regular Type) Class 2 (IEC/JIS) Class II (FDA) Red Laser Diode, 650nm, Max 1mW
  (High Power Type) Class 3R (IEC/JIS) Class IIIa (FDA) Red Laser Diode, 650nm, Max 5mW
Spot Size (see Remark 1) 30 × 100μm 70 × 290μm 300 × 700μm
Linearity (see Remark 2) ±0.1%FS
Resolution (see Remark 3) 1μm 3μm 40μm
Power Supply supplied by CD4A-N/P Controller
Temperature Drift ±0.01% FS/, F°
Laser Emission LED Green = Laser emission
Measurement LED Red = In range, 5% closer than center of measurement range (0 to 45%)
Orange = Within +/- 5% of the center of the measurement range
Green = In range, 5% farther than center of measurement range (55 to 100%)
Red/Green alternating = Out of measurement range
Environmental Rating IP67
Operation Temperature / Humidity -10 to 45 (14 to 113F°), 35 to 85% RH
Storage Temperature / Humidity -20 to 60 (-4 to 140F°), 35 to 85% RH
Ambient illuminance Incandescent Lamp = Max. 3,000 lux
Vibration Resistance 10 to 55 Hz double amplitude 1.5mm for XYZ
Shock Resistance 50G (500m/s2)
Cable 50cm (19.7 inch) cable
Cable Extension CD4CN-S-ROBOT (2m, 78 inch), CD4CN-5S-ROBOT (5m, 197 inch)
Material Aluminum die-cast
 
*1  Defined with center strength 1/e2 (13.5%). There may be leak light other than the spot size.
The sensor may be affected when there is a highly reflective object close to the detection area.
*2  256 times in average (using the special amplifier), object: White Ceramic. The value depends on objects.
*3  The typical value in the conditions of 256 times in average (using the special amplifier), object: White Ceramic, distance range: Middle.
The value depends on objects.
 
  Sensor head (Specular Type)
 
Product Type CD4-L25
Measuring Range 25+/-1mm
Light Source Class 1 (IEC/JIS) Class II (FDA) Red Laser Diode, 650nm, Max 0.39mW
Spot Size (see Remark 1) 25 × 35μm
Linearity (see Remark 2) ±0.1%FS
Resolution (see Remark 3) 0.1μm
Power Supply supplied by CD4A-LN/LP Controller
Temperature Drift ±0.01% FS/ , F°
Laser Emission LED Green = Laser emission
Measurement LED Red = In range, 5% closer than center of measurement range (0 to 45%)
Orange = Within +/- 5% of the center of the measurement range
Green = In range, 5% farther than center of measurement range (55 to 100%)
Red/Green alternating = Out of measurement range
Environmental Rating IP67
Operation Temperature / Humidity -10 to 45 (14 to 113F°), 35 to 85% RH
Storage Temperature / Humidity -20 to 60 (-4 to 140F°), 35 to 85% RH
Ambient illuminance Incandescent Lamp = Max. 3,000 lux
Vibration Resistance 10 to 55 Hz double amplitude 1.5mm for XYZ
Shock Resistance 50G (500m/s2)
Cable 50cm (19.7 inch) cable
Cable Extension CD4CN-S-ROBOT (2m, 78 inch), CD4CN-5S-ROBOT (5m, 197 inch)
Material Aluminum die-cast
 
*1  Defined with center strength 1/e2 (13.5%). There may be leak light other than the spot size.
The sensor may be affected when there is a highly reflective object close to the detection area.
*2  256 times in average (using the special amplifier), object: White Ceramic. The value depends on objects.
*3  The typical value in the conditions of 256 times in average (using the special amplifier), object: White Ceramic, distance range: Middle.
The value depends on objects.
 
  Amplifier Specification
 
Model CD4A-N, CD4A-LN (NPN output type) CD4A-P, CD4A-LP (PNP output type)
Number of connectable sensor heads Max. 2pcs
Sampling frequency 100μs
Supply voltage 12 to 24VDC ±10%
Power consumption 270 mA/24V (When connected 2 sensor heads, with analog current output)
Temperature drift ±0.01% FS/
Analog output ANG(V) [A][B] Voltage output ±5V/FS (Output impedance 100 Ω, resolution 1mV)
ANG(mA) [A][B] Current output 4 to 20 mA/FS (Load impedance 300 Ω, resolution 1.5μA)
Alarm output ALM A, ALM B NPN open collector PNP open collector
Max. 100mA / DC24V (residual voltage Max. 1.8V)
Turn ON then the sensor head fails in measurement
Control output JDGE 1 to 5 NPN open collector PNP open collector
Max. 100mA / DC24V (residual voltage Max. 1.8V)
HI/LO setting and Hysteresis setting are available for each output.
Bank input BANK 0 to 2 ON when connected to GND ON when connected to 12 to 24V
8 banks selectable
Hold input HOLD A, HOLD B, HOLD RST ON when connected to GND ON when connected to 12 to 24V
Laser off or measurement value holding (selectable in the menu)
Zero reset input ZERO A, ZERO B ON when connected to GND ON when connected to 12 to 24V
Zero reset of Head A measurement value / Head B measurement value / Calculation value is available
Optional features Averaging, Filter mode, Calculation, Holding, Alarming, Controlling output,
Analog output, Controlling sensitivity, Timer function, Memory function, Bank function, Zero reset
Display LCD display
Protection category IP20
Operation temperature -10 to 45 (Non condensing) / For storage : -20 to 60
Operating humidity 35 to 85% RH / For storage : 35 to 85% RH
Vibration resistance 10 to 55 Hz double amplitude 1.5mm, 2h for XYZ
Shock resistance 20G (196m/s2)
Material Chassis: Polycarbonate, Connection terminals: Nylon 66
Weight 240g (including connection terminals)
 
Close