D2SA series
Amplifier
The Interconnect Type Amplifiers (Master: D2SA-M, Slave: D2SA-S) can be connected in parallel to provide Cross-talk prevention as well as to transfer settings.
It is possible to connect a maximum of 30 amplifiers together. (12VDC @ 40℃ ambient or less)
2 Amplifier Types (Standalone & Interconnect)
The Interconnect Type amplifiers are convenient when using multiple D2SA amplifiers in parallel.
8 amplifiers can be connected together if the ambient temperature does not exceed 50oC.
A maximum of 30 amplifiers can be connected together, the surrounding temperature must be 40oC or less.
The Interconnect Type amplifiers automatically provide Cross-talk prevention for up to 4 amplifiers.
The D2SA series amplifiers can be connected to Optex-FA's D2RF series fiber optic amplifiers.
Programmable external input
The External input can be programmed to operate in one of the following modes.
・Remote teach
・Synchronizing signal input
・Laser OFF
・Counter reset
2 Independent outputs & Analog
2CH models have two digital outputs for control and/or alarm, there is also a 4~20 mA analog output.
The external input can be configured to operate as needed.
Dual Digital Display
The Threshold value and the Reflected Light level are both indicated at the same time, setting the sensitivity is easy.
Dual Digital DisplayResponse Time
Select the sensing distance and response time based upon your application.
Response TimeCounter Mode
The output turns ON when the count value reaches the preset number.
The preset number can be reset by remote teach.
e-con, the easy connection
Just snap-in the e-con to connect to amplifiers. All the sensor heads are connectable to any amplifier with the preset e-con mechanics.
e-con, the easy connectionIP67 water tightness
All the DS Series sensor heads secures IP67 Water tightness with its rugged housing.
IP67 water tightnessWiring Diagram : (N = NPN, P=PNP)
Wiring Diagram : (N = NPN, P=PNP)A choice of 6 convenient Teach functions to solve any application.
Single Point Teach
Single Point TeachUse this teaching mode when no target is present.
Set the threshold so the sensor does not detect the background.
Two Point Teach
Two Point TeachThis is the basic setting method for the DSD-100 Diffuse Reflective type sensor.
First teach with the target present and then teach the background.
The threshold is then set between the target value and the background.
Transparent Object Teach
This mode is only for the DSR-800 Retro-Reflective sensor.
Teach without the target present so that the sensor is set to the maximum sensitivity, the DSR-800 is able to easily detect transparent film, bottles, glass, etc.
Automatic Teach
Automatic TeachIn this mode there is no reason to stop the conveyor.
It is possible to teach the sensor while the product is running.
Zone Teach
Zone TeachSelect the detection area.
Use the Up / Down buttons to set the area within +/- 10%.
After teaching this area can be increased or decreased by adjusting the settings.
Judgement Teach
Judgement TeachThis function is exclusive to the DSTA-200 wide beam measurement sensing heads.
Used to judge the size and width of a target within +/- 10% of the specified size.
Even if the object position changes the sensor will detect it, so this is actually Area Teach.